.\" Automatically generated by Pod::Man v1.37, Pod::Parser v1.35 .\" .\" Standard preamble: .\" ======================================================================== .de Sh \" Subsection heading .br .if t .Sp .ne 5 .PP \fB\\$1\fR .PP .. .de Sp \" Vertical space (when we can't use .PP) .if t .sp .5v .if n .sp .. .de Vb \" Begin verbatim text .ft CW .nf .ne \\$1 .. .de Ve \" End verbatim text .ft R .fi .. .\" Set up some character translations and predefined strings. \*(-- will .\" give an unbreakable dash, \*(PI will give pi, \*(L" will give a left .\" double quote, and \*(R" will give a right double quote. | will give a .\" real vertical bar. \*(C+ will give a nicer C++. Capital omega is used to .\" do unbreakable dashes and therefore won't be available. \*(C` and \*(C' .\" expand to `' in nroff, nothing in troff, for use with C<>. .tr \(*W-|\(bv\*(Tr .ds C+ C\v'-.1v'\h'-1p'\s-2+\h'-1p'+\s0\v'.1v'\h'-1p' .ie n \{\ . ds -- \(*W- . ds PI pi . if (\n(.H=4u)&(1m=24u) .ds -- \(*W\h'-12u'\(*W\h'-12u'-\" diablo 10 pitch . if (\n(.H=4u)&(1m=20u) .ds -- \(*W\h'-12u'\(*W\h'-8u'-\" diablo 12 pitch . ds L" "" . ds R" "" . ds C` "" . ds C' "" 'br\} .el\{\ . ds -- \|\(em\| . ds PI \(*p . ds L" `` . ds R" '' 'br\} .\" .\" If the F register is turned on, we'll generate index entries on stderr for .\" titles (.TH), headers (.SH), subsections (.Sh), items (.Ip), and index .\" entries marked with X<> in POD. Of course, you'll have to process the .\" output yourself in some meaningful fashion. .if \nF \{\ . de IX . tm Index:\\$1\t\\n%\t"\\$2" .. . nr % 0 . rr F .\} .\" .\" For nroff, turn off justification. Always turn off hyphenation; it makes .\" way too many mistakes in technical documents. .hy 0 .if n .na .\" .\" Accent mark definitions (@(#)ms.acc 1.5 88/02/08 SMI; from UCB 4.2). .\" Fear. Run. Save yourself. No user-serviceable parts. . \" fudge factors for nroff and troff .if n \{\ . ds #H 0 . ds #V .8m . ds #F .3m . ds #[ \f1 . ds #] \fP .\} .if t \{\ . ds #H ((1u-(\\\\n(.fu%2u))*.13m) . ds #V .6m . ds #F 0 . ds #[ \& . ds #] \& .\} . \" simple accents for nroff and troff .if n \{\ . ds ' \& . ds ` \& . ds ^ \& . ds , \& . ds ~ ~ . ds / .\} .if t \{\ . ds ' \\k:\h'-(\\n(.wu*8/10-\*(#H)'\'\h"|\\n:u" . ds ` \\k:\h'-(\\n(.wu*8/10-\*(#H)'\`\h'|\\n:u' . ds ^ \\k:\h'-(\\n(.wu*10/11-\*(#H)'^\h'|\\n:u' . ds , \\k:\h'-(\\n(.wu*8/10)',\h'|\\n:u' . ds ~ \\k:\h'-(\\n(.wu-\*(#H-.1m)'~\h'|\\n:u' . ds / \\k:\h'-(\\n(.wu*8/10-\*(#H)'\z\(sl\h'|\\n:u' .\} . \" troff and (daisy-wheel) nroff accents .ds : \\k:\h'-(\\n(.wu*8/10-\*(#H+.1m+\*(#F)'\v'-\*(#V'\z.\h'.2m+\*(#F'.\h'|\\n:u'\v'\*(#V' .ds 8 \h'\*(#H'\(*b\h'-\*(#H' .ds o \\k:\h'-(\\n(.wu+\w'\(de'u-\*(#H)/2u'\v'-.3n'\*(#[\z\(de\v'.3n'\h'|\\n:u'\*(#] .ds d- \h'\*(#H'\(pd\h'-\w'~'u'\v'-.25m'\f2\(hy\fP\v'.25m'\h'-\*(#H' .ds D- D\\k:\h'-\w'D'u'\v'-.11m'\z\(hy\v'.11m'\h'|\\n:u' .ds th \*(#[\v'.3m'\s+1I\s-1\v'-.3m'\h'-(\w'I'u*2/3)'\s-1o\s+1\*(#] .ds Th \*(#[\s+2I\s-2\h'-\w'I'u*3/5'\v'-.3m'o\v'.3m'\*(#] .ds ae a\h'-(\w'a'u*4/10)'e .ds Ae A\h'-(\w'A'u*4/10)'E . \" corrections for vroff .if v .ds ~ \\k:\h'-(\\n(.wu*9/10-\*(#H)'\s-2\u~\d\s+2\h'|\\n:u' .if v .ds ^ \\k:\h'-(\\n(.wu*10/11-\*(#H)'\v'-.4m'^\v'.4m'\h'|\\n:u' . \" for low resolution devices (crt and lpr) .if \n(.H>23 .if \n(.V>19 \ \{\ . ds : e . ds 8 ss . ds o a . ds d- d\h'-1'\(ga . ds D- D\h'-1'\(hy . ds th \o'bp' . ds Th \o'LP' . ds ae ae . ds Ae AE .\} .rm #[ #] #H #V #F C .\" ======================================================================== .\" .IX Title "EV 1" .TH EV 1 "2007-12-25" "perl v5.8.8" "User Contributed Perl Documentation" .SH "NAME" libev \- a high performance full\-featured event loop written in C .SH "SYNOPSIS" .IX Header "SYNOPSIS" .Vb 1 \& #include <ev.h> .Ve .Sh "\s-1EXAMPLE\s0 \s-1PROGRAM\s0" .IX Subsection "EXAMPLE PROGRAM" .Vb 1 \& #include <ev.h> .Ve .PP .Vb 2 \& ev_io stdin_watcher; \& ev_timer timeout_watcher; .Ve .PP .Vb 8 \& /* called when data readable on stdin */ \& static void \& stdin_cb (EV_P_ struct ev_io *w, int revents) \& { \& /* puts ("stdin ready"); */ \& ev_io_stop (EV_A_ w); /* just a syntax example */ \& ev_unloop (EV_A_ EVUNLOOP_ALL); /* leave all loop calls */ \& } .Ve .PP .Vb 6 \& static void \& timeout_cb (EV_P_ struct ev_timer *w, int revents) \& { \& /* puts ("timeout"); */ \& ev_unloop (EV_A_ EVUNLOOP_ONE); /* leave one loop call */ \& } .Ve .PP .Vb 4 \& int \& main (void) \& { \& struct ev_loop *loop = ev_default_loop (0); .Ve .PP .Vb 3 \& /* initialise an io watcher, then start it */ \& ev_io_init (&stdin_watcher, stdin_cb, /*STDIN_FILENO*/ 0, EV_READ); \& ev_io_start (loop, &stdin_watcher); .Ve .PP .Vb 3 \& /* simple non-repeating 5.5 second timeout */ \& ev_timer_init (&timeout_watcher, timeout_cb, 5.5, 0.); \& ev_timer_start (loop, &timeout_watcher); .Ve .PP .Vb 2 \& /* loop till timeout or data ready */ \& ev_loop (loop, 0); .Ve .PP .Vb 2 \& return 0; \& } .Ve .SH "DESCRIPTION" .IX Header "DESCRIPTION" The newest version of this document is also available as a html-formatted web page you might find easier to navigate when reading it for the first time: <http://cvs.schmorp.de/libev/ev.html>. .PP Libev is an event loop: you register interest in certain events (such as a file descriptor being readable or a timeout occurring), and it will manage these event sources and provide your program with events. .PP To do this, it must take more or less complete control over your process (or thread) by executing the \fIevent loop\fR handler, and will then communicate events via a callback mechanism. .PP You register interest in certain events by registering so-called \fIevent watchers\fR, which are relatively small C structures you initialise with the details of the event, and then hand it over to libev by \fIstarting\fR the watcher. .Sh "\s-1FEATURES\s0" .IX Subsection "FEATURES" Libev supports \f(CW\*(C`select\*(C'\fR, \f(CW\*(C`poll\*(C'\fR, the Linux-specific \f(CW\*(C`epoll\*(C'\fR, the BSD-specific \f(CW\*(C`kqueue\*(C'\fR and the Solaris-specific event port mechanisms for file descriptor events (\f(CW\*(C`ev_io\*(C'\fR), the Linux \f(CW\*(C`inotify\*(C'\fR interface (for \f(CW\*(C`ev_stat\*(C'\fR), relative timers (\f(CW\*(C`ev_timer\*(C'\fR), absolute timers with customised rescheduling (\f(CW\*(C`ev_periodic\*(C'\fR), synchronous signals (\f(CW\*(C`ev_signal\*(C'\fR), process status change events (\f(CW\*(C`ev_child\*(C'\fR), and event watchers dealing with the event loop mechanism itself (\f(CW\*(C`ev_idle\*(C'\fR, \&\f(CW\*(C`ev_embed\*(C'\fR, \f(CW\*(C`ev_prepare\*(C'\fR and \f(CW\*(C`ev_check\*(C'\fR watchers) as well as file watchers (\f(CW\*(C`ev_stat\*(C'\fR) and even limited support for fork events (\f(CW\*(C`ev_fork\*(C'\fR). .PP It also is quite fast (see this benchmark comparing it to libevent for example). .Sh "\s-1CONVENTIONS\s0" .IX Subsection "CONVENTIONS" Libev is very configurable. In this manual the default configuration will be described, which supports multiple event loops. For more info about various configuration options please have a look at \fB\s-1EMBED\s0\fR section in this manual. If libev was configured without support for multiple event loops, then all functions taking an initial argument of name \f(CW\*(C`loop\*(C'\fR (which is always of type \f(CW\*(C`struct ev_loop *\*(C'\fR) will not have this argument. .Sh "\s-1TIME\s0 \s-1REPRESENTATION\s0" .IX Subsection "TIME REPRESENTATION" Libev represents time as a single floating point number, representing the (fractional) number of seconds since the (\s-1POSIX\s0) epoch (somewhere near the beginning of 1970, details are complicated, don't ask). This type is called \f(CW\*(C`ev_tstamp\*(C'\fR, which is what you should use too. It usually aliases to the \f(CW\*(C`double\*(C'\fR type in C, and when you need to do any calculations on it, you should treat it as some floatingpoint value. Unlike the name component \f(CW\*(C`stamp\*(C'\fR might indicate, it is also used for time differences throughout libev. .SH "GLOBAL FUNCTIONS" .IX Header "GLOBAL FUNCTIONS" These functions can be called anytime, even before initialising the library in any way. .IP "ev_tstamp ev_time ()" 4 .IX Item "ev_tstamp ev_time ()" Returns the current time as libev would use it. Please note that the \&\f(CW\*(C`ev_now\*(C'\fR function is usually faster and also often returns the timestamp you actually want to know. .IP "ev_sleep (ev_tstamp interval)" 4 .IX Item "ev_sleep (ev_tstamp interval)" Sleep for the given interval: The current thread will be blocked until either it is interrupted or the given time interval has passed. Basically this is a subsecond-resolution \f(CW\*(C`sleep ()\*(C'\fR. .IP "int ev_version_major ()" 4 .IX Item "int ev_version_major ()" .PD 0 .IP "int ev_version_minor ()" 4 .IX Item "int ev_version_minor ()" .PD You can find out the major and minor \s-1ABI\s0 version numbers of the library you linked against by calling the functions \f(CW\*(C`ev_version_major\*(C'\fR and \&\f(CW\*(C`ev_version_minor\*(C'\fR. If you want, you can compare against the global symbols \f(CW\*(C`EV_VERSION_MAJOR\*(C'\fR and \f(CW\*(C`EV_VERSION_MINOR\*(C'\fR, which specify the version of the library your program was compiled against. .Sp These version numbers refer to the \s-1ABI\s0 version of the library, not the release version. .Sp Usually, it's a good idea to terminate if the major versions mismatch, as this indicates an incompatible change. Minor versions are usually compatible to older versions, so a larger minor version alone is usually not a problem. .Sp Example: Make sure we haven't accidentally been linked against the wrong version. .Sp .Vb 3 \& assert (("libev version mismatch", \& ev_version_major () == EV_VERSION_MAJOR \& && ev_version_minor () >= EV_VERSION_MINOR)); .Ve .IP "unsigned int ev_supported_backends ()" 4 .IX Item "unsigned int ev_supported_backends ()" Return the set of all backends (i.e. their corresponding \f(CW\*(C`EV_BACKEND_*\*(C'\fR value) compiled into this binary of libev (independent of their availability on the system you are running on). See \f(CW\*(C`ev_default_loop\*(C'\fR for a description of the set values. .Sp Example: make sure we have the epoll method, because yeah this is cool and a must have and can we have a torrent of it please!!!11 .Sp .Vb 2 \& assert (("sorry, no epoll, no sex", \& ev_supported_backends () & EVBACKEND_EPOLL)); .Ve .IP "unsigned int ev_recommended_backends ()" 4 .IX Item "unsigned int ev_recommended_backends ()" Return the set of all backends compiled into this binary of libev and also recommended for this platform. This set is often smaller than the one returned by \f(CW\*(C`ev_supported_backends\*(C'\fR, as for example kqueue is broken on most BSDs and will not be autodetected unless you explicitly request it (assuming you know what you are doing). This is the set of backends that libev will probe for if you specify no backends explicitly. .IP "unsigned int ev_embeddable_backends ()" 4 .IX Item "unsigned int ev_embeddable_backends ()" Returns the set of backends that are embeddable in other event loops. This is the theoretical, all\-platform, value. To find which backends might be supported on the current system, you would need to look at \&\f(CW\*(C`ev_embeddable_backends () & ev_supported_backends ()\*(C'\fR, likewise for recommended ones. .Sp See the description of \f(CW\*(C`ev_embed\*(C'\fR watchers for more info. .IP "ev_set_allocator (void *(*cb)(void *ptr, long size))" 4 .IX Item "ev_set_allocator (void *(*cb)(void *ptr, long size))" Sets the allocation function to use (the prototype is similar \- the semantics is identical \- to the realloc C function). It is used to allocate and free memory (no surprises here). If it returns zero when memory needs to be allocated, the library might abort or take some potentially destructive action. The default is your system realloc function. .Sp You could override this function in high-availability programs to, say, free some memory if it cannot allocate memory, to use a special allocator, or even to sleep a while and retry until some memory is available. .Sp Example: Replace the libev allocator with one that waits a bit and then retries). .Sp .Vb 6 \& static void * \& persistent_realloc (void *ptr, size_t size) \& { \& for (;;) \& { \& void *newptr = realloc (ptr, size); .Ve .Sp .Vb 2 \& if (newptr) \& return newptr; .Ve .Sp .Vb 3 \& sleep (60); \& } \& } .Ve .Sp .Vb 2 \& ... \& ev_set_allocator (persistent_realloc); .Ve .IP "ev_set_syserr_cb (void (*cb)(const char *msg));" 4 .IX Item "ev_set_syserr_cb (void (*cb)(const char *msg));" Set the callback function to call on a retryable syscall error (such as failed select, poll, epoll_wait). The message is a printable string indicating the system call or subsystem causing the problem. If this callback is set, then libev will expect it to remedy the sitution, no matter what, when it returns. That is, libev will generally retry the requested operation, or, if the condition doesn't go away, do bad stuff (such as abort). .Sp Example: This is basically the same thing that libev does internally, too. .Sp .Vb 6 \& static void \& fatal_error (const char *msg) \& { \& perror (msg); \& abort (); \& } .Ve .Sp .Vb 2 \& ... \& ev_set_syserr_cb (fatal_error); .Ve .SH "FUNCTIONS CONTROLLING THE EVENT LOOP" .IX Header "FUNCTIONS CONTROLLING THE EVENT LOOP" An event loop is described by a \f(CW\*(C`struct ev_loop *\*(C'\fR. The library knows two types of such loops, the \fIdefault\fR loop, which supports signals and child events, and dynamically created loops which do not. .PP If you use threads, a common model is to run the default event loop in your main thread (or in a separate thread) and for each thread you create, you also create another event loop. Libev itself does no locking whatsoever, so if you mix calls to the same event loop in different threads, make sure you lock (this is usually a bad idea, though, even if done correctly, because it's hideous and inefficient). .IP "struct ev_loop *ev_default_loop (unsigned int flags)" 4 .IX Item "struct ev_loop *ev_default_loop (unsigned int flags)" This will initialise the default event loop if it hasn't been initialised yet and return it. If the default loop could not be initialised, returns false. If it already was initialised it simply returns it (and ignores the flags. If that is troubling you, check \f(CW\*(C`ev_backend ()\*(C'\fR afterwards). .Sp If you don't know what event loop to use, use the one returned from this function. .Sp The flags argument can be used to specify special behaviour or specific backends to use, and is usually specified as \f(CW0\fR (or \f(CW\*(C`EVFLAG_AUTO\*(C'\fR). .Sp The following flags are supported: .RS 4 .ie n .IP """EVFLAG_AUTO""" 4 .el .IP "\f(CWEVFLAG_AUTO\fR" 4 .IX Item "EVFLAG_AUTO" The default flags value. Use this if you have no clue (it's the right thing, believe me). .ie n .IP """EVFLAG_NOENV""" 4 .el .IP "\f(CWEVFLAG_NOENV\fR" 4 .IX Item "EVFLAG_NOENV" If this flag bit is ored into the flag value (or the program runs setuid or setgid) then libev will \fInot\fR look at the environment variable \&\f(CW\*(C`LIBEV_FLAGS\*(C'\fR. Otherwise (the default), this environment variable will override the flags completely if it is found in the environment. This is useful to try out specific backends to test their performance, or to work around bugs. .ie n .IP """EVFLAG_FORKCHECK""" 4 .el .IP "\f(CWEVFLAG_FORKCHECK\fR" 4 .IX Item "EVFLAG_FORKCHECK" Instead of calling \f(CW\*(C`ev_default_fork\*(C'\fR or \f(CW\*(C`ev_loop_fork\*(C'\fR manually after a fork, you can also make libev check for a fork in each iteration by enabling this flag. .Sp This works by calling \f(CW\*(C`getpid ()\*(C'\fR on every iteration of the loop, and thus this might slow down your event loop if you do a lot of loop iterations and little real work, but is usually not noticeable (on my Linux system for example, \f(CW\*(C`getpid\*(C'\fR is actually a simple 5\-insn sequence without a syscall and thus \fIvery\fR fast, but my Linux system also has \&\f(CW\*(C`pthread_atfork\*(C'\fR which is even faster). .Sp The big advantage of this flag is that you can forget about fork (and forget about forgetting to tell libev about forking) when you use this flag. .Sp This flag setting cannot be overriden or specified in the \f(CW\*(C`LIBEV_FLAGS\*(C'\fR environment variable. .ie n .IP """EVBACKEND_SELECT"" (value 1, portable select backend)" 4 .el .IP "\f(CWEVBACKEND_SELECT\fR (value 1, portable select backend)" 4 .IX Item "EVBACKEND_SELECT (value 1, portable select backend)" This is your standard \fIselect\fR\|(2) backend. Not \fIcompletely\fR standard, as libev tries to roll its own fd_set with no limits on the number of fds, but if that fails, expect a fairly low limit on the number of fds when using this backend. It doesn't scale too well (O(highest_fd)), but its usually the fastest backend for a low number of (low\-numbered :) fds. .Sp To get good performance out of this backend you need a high amount of parallelity (most of the file descriptors should be busy). If you are writing a server, you should \f(CW\*(C`accept ()\*(C'\fR in a loop to accept as many connections as possible during one iteration. You might also want to have a look at \f(CW\*(C`ev_set_io_collect_interval ()\*(C'\fR to increase the amount of readyness notifications you get per iteration. .ie n .IP """EVBACKEND_POLL"" (value 2, poll backend, available everywhere except on windows)" 4 .el .IP "\f(CWEVBACKEND_POLL\fR (value 2, poll backend, available everywhere except on windows)" 4 .IX Item "EVBACKEND_POLL (value 2, poll backend, available everywhere except on windows)" And this is your standard \fIpoll\fR\|(2) backend. It's more complicated than select, but handles sparse fds better and has no artificial limit on the number of fds you can use (except it will slow down considerably with a lot of inactive fds). It scales similarly to select, i.e. O(total_fds). See the entry for \f(CW\*(C`EVBACKEND_SELECT\*(C'\fR, above, for performance tips. .ie n .IP """EVBACKEND_EPOLL"" (value 4, Linux)" 4 .el .IP "\f(CWEVBACKEND_EPOLL\fR (value 4, Linux)" 4 .IX Item "EVBACKEND_EPOLL (value 4, Linux)" For few fds, this backend is a bit little slower than poll and select, but it scales phenomenally better. While poll and select usually scale like O(total_fds) where n is the total number of fds (or the highest fd), epoll scales either O(1) or O(active_fds). The epoll design has a number of shortcomings, such as silently dropping events in some hard-to-detect cases and rewiring a syscall per fd change, no fork support and bad support for dup. .Sp While stopping, setting and starting an I/O watcher in the same iteration will result in some caching, there is still a syscall per such incident (because the fd could point to a different file description now), so its best to avoid that. Also, \f(CW\*(C`dup ()\*(C'\fR'ed file descriptors might not work very well if you register events for both fds. .Sp Please note that epoll sometimes generates spurious notifications, so you need to use non-blocking I/O or other means to avoid blocking when no data (or space) is available. .Sp Best performance from this backend is achieved by not unregistering all watchers for a file descriptor until it has been closed, if possible, i.e. keep at least one watcher active per fd at all times. .Sp While nominally embeddeble in other event loops, this feature is broken in all kernel versions tested so far. .ie n .IP """EVBACKEND_KQUEUE"" (value 8, most \s-1BSD\s0 clones)" 4 .el .IP "\f(CWEVBACKEND_KQUEUE\fR (value 8, most \s-1BSD\s0 clones)" 4 .IX Item "EVBACKEND_KQUEUE (value 8, most BSD clones)" Kqueue deserves special mention, as at the time of this writing, it was broken on all BSDs except NetBSD (usually it doesn't work reliably with anything but sockets and pipes, except on Darwin, where of course it's completely useless). For this reason it's not being \*(L"autodetected\*(R" unless you explicitly specify it explicitly in the flags (i.e. using \&\f(CW\*(C`EVBACKEND_KQUEUE\*(C'\fR) or libev was compiled on a known-to-be-good (\-enough) system like NetBSD. .Sp You still can embed kqueue into a normal poll or select backend and use it only for sockets (after having made sure that sockets work with kqueue on the target platform). See \f(CW\*(C`ev_embed\*(C'\fR watchers for more info. .Sp It scales in the same way as the epoll backend, but the interface to the kernel is more efficient (which says nothing about its actual speed, of course). While stopping, setting and starting an I/O watcher does never cause an extra syscall as with \f(CW\*(C`EVBACKEND_EPOLL\*(C'\fR, it still adds up to two event changes per incident, support for \f(CW\*(C`fork ()\*(C'\fR is very bad and it drops fds silently in similarly hard-to-detect cases. .Sp This backend usually performs well under most conditions. .Sp While nominally embeddable in other event loops, this doesn't work everywhere, so you might need to test for this. And since it is broken almost everywhere, you should only use it when you have a lot of sockets (for which it usually works), by embedding it into another event loop (e.g. \f(CW\*(C`EVBACKEND_SELECT\*(C'\fR or \f(CW\*(C`EVBACKEND_POLL\*(C'\fR) and using it only for sockets. .ie n .IP """EVBACKEND_DEVPOLL"" (value 16, Solaris 8)" 4 .el .IP "\f(CWEVBACKEND_DEVPOLL\fR (value 16, Solaris 8)" 4 .IX Item "EVBACKEND_DEVPOLL (value 16, Solaris 8)" This is not implemented yet (and might never be, unless you send me an implementation). According to reports, \f(CW\*(C`/dev/poll\*(C'\fR only supports sockets and is not embeddable, which would limit the usefulness of this backend immensely. .ie n .IP """EVBACKEND_PORT"" (value 32, Solaris 10)" 4 .el .IP "\f(CWEVBACKEND_PORT\fR (value 32, Solaris 10)" 4 .IX Item "EVBACKEND_PORT (value 32, Solaris 10)" This uses the Solaris 10 event port mechanism. As with everything on Solaris, it's really slow, but it still scales very well (O(active_fds)). .Sp Please note that solaris event ports can deliver a lot of spurious notifications, so you need to use non-blocking I/O or other means to avoid blocking when no data (or space) is available. .Sp While this backend scales well, it requires one system call per active file descriptor per loop iteration. For small and medium numbers of file descriptors a \*(L"slow\*(R" \f(CW\*(C`EVBACKEND_SELECT\*(C'\fR or \f(CW\*(C`EVBACKEND_POLL\*(C'\fR backend might perform better. .ie n .IP """EVBACKEND_ALL""" 4 .el .IP "\f(CWEVBACKEND_ALL\fR" 4 .IX Item "EVBACKEND_ALL" Try all backends (even potentially broken ones that wouldn't be tried with \f(CW\*(C`EVFLAG_AUTO\*(C'\fR). Since this is a mask, you can do stuff such as \&\f(CW\*(C`EVBACKEND_ALL & ~EVBACKEND_KQUEUE\*(C'\fR. .Sp It is definitely not recommended to use this flag. .RE .RS 4 .Sp If one or more of these are ored into the flags value, then only these backends will be tried (in the reverse order as given here). If none are specified, most compiled-in backend will be tried, usually in reverse order of their flag values :) .Sp The most typical usage is like this: .Sp .Vb 2 \& if (!ev_default_loop (0)) \& fatal ("could not initialise libev, bad $LIBEV_FLAGS in environment?"); .Ve .Sp Restrict libev to the select and poll backends, and do not allow environment settings to be taken into account: .Sp .Vb 1 \& ev_default_loop (EVBACKEND_POLL | EVBACKEND_SELECT | EVFLAG_NOENV); .Ve .Sp Use whatever libev has to offer, but make sure that kqueue is used if available (warning, breaks stuff, best use only with your own private event loop and only if you know the \s-1OS\s0 supports your types of fds): .Sp .Vb 1 \& ev_default_loop (ev_recommended_backends () | EVBACKEND_KQUEUE); .Ve .RE .IP "struct ev_loop *ev_loop_new (unsigned int flags)" 4 .IX Item "struct ev_loop *ev_loop_new (unsigned int flags)" Similar to \f(CW\*(C`ev_default_loop\*(C'\fR, but always creates a new event loop that is always distinct from the default loop. Unlike the default loop, it cannot handle signal and child watchers, and attempts to do so will be greeted by undefined behaviour (or a failed assertion if assertions are enabled). .Sp Example: Try to create a event loop that uses epoll and nothing else. .Sp .Vb 3 \& struct ev_loop *epoller = ev_loop_new (EVBACKEND_EPOLL | EVFLAG_NOENV); \& if (!epoller) \& fatal ("no epoll found here, maybe it hides under your chair"); .Ve .IP "ev_default_destroy ()" 4 .IX Item "ev_default_destroy ()" Destroys the default loop again (frees all memory and kernel state etc.). None of the active event watchers will be stopped in the normal sense, so e.g. \f(CW\*(C`ev_is_active\*(C'\fR might still return true. It is your responsibility to either stop all watchers cleanly yoursef \fIbefore\fR calling this function, or cope with the fact afterwards (which is usually the easiest thing, you can just ignore the watchers and/or \f(CW\*(C`free ()\*(C'\fR them for example). .Sp Note that certain global state, such as signal state, will not be freed by this function, and related watchers (such as signal and child watchers) would need to be stopped manually. .Sp In general it is not advisable to call this function except in the rare occasion where you really need to free e.g. the signal handling pipe fds. If you need dynamically allocated loops it is better to use \&\f(CW\*(C`ev_loop_new\*(C'\fR and \f(CW\*(C`ev_loop_destroy\*(C'\fR). .IP "ev_loop_destroy (loop)" 4 .IX Item "ev_loop_destroy (loop)" Like \f(CW\*(C`ev_default_destroy\*(C'\fR, but destroys an event loop created by an earlier call to \f(CW\*(C`ev_loop_new\*(C'\fR. .IP "ev_default_fork ()" 4 .IX Item "ev_default_fork ()" This function reinitialises the kernel state for backends that have one. Despite the name, you can call it anytime, but it makes most sense after forking, in either the parent or child process (or both, but that again makes little sense). .Sp You \fImust\fR call this function in the child process after forking if and only if you want to use the event library in both processes. If you just fork+exec, you don't have to call it. .Sp The function itself is quite fast and it's usually not a problem to call it just in case after a fork. To make this easy, the function will fit in quite nicely into a call to \f(CW\*(C`pthread_atfork\*(C'\fR: .Sp .Vb 1 \& pthread_atfork (0, 0, ev_default_fork); .Ve .Sp At the moment, \f(CW\*(C`EVBACKEND_SELECT\*(C'\fR and \f(CW\*(C`EVBACKEND_POLL\*(C'\fR are safe to use without calling this function, so if you force one of those backends you do not need to care. .IP "ev_loop_fork (loop)" 4 .IX Item "ev_loop_fork (loop)" Like \f(CW\*(C`ev_default_fork\*(C'\fR, but acts on an event loop created by \&\f(CW\*(C`ev_loop_new\*(C'\fR. Yes, you have to call this on every allocated event loop after fork, and how you do this is entirely your own problem. .IP "unsigned int ev_loop_count (loop)" 4 .IX Item "unsigned int ev_loop_count (loop)" Returns the count of loop iterations for the loop, which is identical to the number of times libev did poll for new events. It starts at \f(CW0\fR and happily wraps around with enough iterations. .Sp This value can sometimes be useful as a generation counter of sorts (it \&\*(L"ticks\*(R" the number of loop iterations), as it roughly corresponds with \&\f(CW\*(C`ev_prepare\*(C'\fR and \f(CW\*(C`ev_check\*(C'\fR calls. .IP "unsigned int ev_backend (loop)" 4 .IX Item "unsigned int ev_backend (loop)" Returns one of the \f(CW\*(C`EVBACKEND_*\*(C'\fR flags indicating the event backend in use. .IP "ev_tstamp ev_now (loop)" 4 .IX Item "ev_tstamp ev_now (loop)" Returns the current \*(L"event loop time\*(R", which is the time the event loop received events and started processing them. This timestamp does not change as long as callbacks are being processed, and this is also the base time used for relative timers. You can treat it as the timestamp of the event occurring (or more correctly, libev finding out about it). .IP "ev_loop (loop, int flags)" 4 .IX Item "ev_loop (loop, int flags)" Finally, this is it, the event handler. This function usually is called after you initialised all your watchers and you want to start handling events. .Sp If the flags argument is specified as \f(CW0\fR, it will not return until either no event watchers are active anymore or \f(CW\*(C`ev_unloop\*(C'\fR was called. .Sp Please note that an explicit \f(CW\*(C`ev_unloop\*(C'\fR is usually better than relying on all watchers to be stopped when deciding when a program has finished (especially in interactive programs), but having a program that automatically loops as long as it has to and no longer by virtue of relying on its watchers stopping correctly is a thing of beauty. .Sp A flags value of \f(CW\*(C`EVLOOP_NONBLOCK\*(C'\fR will look for new events, will handle those events and any outstanding ones, but will not block your process in case there are no events and will return after one iteration of the loop. .Sp A flags value of \f(CW\*(C`EVLOOP_ONESHOT\*(C'\fR will look for new events (waiting if neccessary) and will handle those and any outstanding ones. It will block your process until at least one new event arrives, and will return after one iteration of the loop. This is useful if you are waiting for some external event in conjunction with something not expressible using other libev watchers. However, a pair of \f(CW\*(C`ev_prepare\*(C'\fR/\f(CW\*(C`ev_check\*(C'\fR watchers is usually a better approach for this kind of thing. .Sp Here are the gory details of what \f(CW\*(C`ev_loop\*(C'\fR does: .Sp .Vb 19 \& - Before the first iteration, call any pending watchers. \& * If there are no active watchers (reference count is zero), return. \& - Queue all prepare watchers and then call all outstanding watchers. \& - If we have been forked, recreate the kernel state. \& - Update the kernel state with all outstanding changes. \& - Update the "event loop time". \& - Calculate for how long to block. \& - Block the process, waiting for any events. \& - Queue all outstanding I/O (fd) events. \& - Update the "event loop time" and do time jump handling. \& - Queue all outstanding timers. \& - Queue all outstanding periodics. \& - If no events are pending now, queue all idle watchers. \& - Queue all check watchers. \& - Call all queued watchers in reverse order (i.e. check watchers first). \& Signals and child watchers are implemented as I/O watchers, and will \& be handled here by queueing them when their watcher gets executed. \& - If ev_unloop has been called or EVLOOP_ONESHOT or EVLOOP_NONBLOCK \& were used, return, otherwise continue with step *. .Ve .Sp Example: Queue some jobs and then loop until no events are outsanding anymore. .Sp .Vb 4 \& ... queue jobs here, make sure they register event watchers as long \& ... as they still have work to do (even an idle watcher will do..) \& ev_loop (my_loop, 0); \& ... jobs done. yeah! .Ve .IP "ev_unloop (loop, how)" 4 .IX Item "ev_unloop (loop, how)" Can be used to make a call to \f(CW\*(C`ev_loop\*(C'\fR return early (but only after it has processed all outstanding events). The \f(CW\*(C`how\*(C'\fR argument must be either \&\f(CW\*(C`EVUNLOOP_ONE\*(C'\fR, which will make the innermost \f(CW\*(C`ev_loop\*(C'\fR call return, or \&\f(CW\*(C`EVUNLOOP_ALL\*(C'\fR, which will make all nested \f(CW\*(C`ev_loop\*(C'\fR calls return. .IP "ev_ref (loop)" 4 .IX Item "ev_ref (loop)" .PD 0 .IP "ev_unref (loop)" 4 .IX Item "ev_unref (loop)" .PD Ref/unref can be used to add or remove a reference count on the event loop: Every watcher keeps one reference, and as long as the reference count is nonzero, \f(CW\*(C`ev_loop\*(C'\fR will not return on its own. If you have a watcher you never unregister that should not keep \f(CW\*(C`ev_loop\*(C'\fR from returning, \fIev_unref()\fR after starting, and \fIev_ref()\fR before stopping it. For example, libev itself uses this for its internal signal pipe: It is not visible to the libev user and should not keep \f(CW\*(C`ev_loop\*(C'\fR from exiting if no event watchers registered by it are active. It is also an excellent way to do this for generic recurring timers or from within third-party libraries. Just remember to \fIunref after start\fR and \fIref before stop\fR. .Sp Example: Create a signal watcher, but keep it from keeping \f(CW\*(C`ev_loop\*(C'\fR running when nothing else is active. .Sp .Vb 4 \& struct ev_signal exitsig; \& ev_signal_init (&exitsig, sig_cb, SIGINT); \& ev_signal_start (loop, &exitsig); \& evf_unref (loop); .Ve .Sp Example: For some weird reason, unregister the above signal handler again. .Sp .Vb 2 \& ev_ref (loop); \& ev_signal_stop (loop, &exitsig); .Ve .IP "ev_set_io_collect_interval (loop, ev_tstamp interval)" 4 .IX Item "ev_set_io_collect_interval (loop, ev_tstamp interval)" .PD 0 .IP "ev_set_timeout_collect_interval (loop, ev_tstamp interval)" 4 .IX Item "ev_set_timeout_collect_interval (loop, ev_tstamp interval)" .PD These advanced functions influence the time that libev will spend waiting for events. Both are by default \f(CW0\fR, meaning that libev will try to invoke timer/periodic callbacks and I/O callbacks with minimum latency. .Sp Setting these to a higher value (the \f(CW\*(C`interval\*(C'\fR \fImust\fR be >= \f(CW0\fR) allows libev to delay invocation of I/O and timer/periodic callbacks to increase efficiency of loop iterations. .Sp The background is that sometimes your program runs just fast enough to handle one (or very few) event(s) per loop iteration. While this makes the program responsive, it also wastes a lot of \s-1CPU\s0 time to poll for new events, especially with backends like \f(CW\*(C`select ()\*(C'\fR which have a high overhead for the actual polling but can deliver many events at once. .Sp By setting a higher \fIio collect interval\fR you allow libev to spend more time collecting I/O events, so you can handle more events per iteration, at the cost of increasing latency. Timeouts (both \f(CW\*(C`ev_periodic\*(C'\fR and \&\f(CW\*(C`ev_timer\*(C'\fR) will be not affected. Setting this to a non-null value will introduce an additional \f(CW\*(C`ev_sleep ()\*(C'\fR call into most loop iterations. .Sp Likewise, by setting a higher \fItimeout collect interval\fR you allow libev to spend more time collecting timeouts, at the expense of increased latency (the watcher callback will be called later). \f(CW\*(C`ev_io\*(C'\fR watchers will not be affected. Setting this to a non-null value will not introduce any overhead in libev. .Sp Many (busy) programs can usually benefit by setting the io collect interval to a value near \f(CW0.1\fR or so, which is often enough for interactive servers (of course not for games), likewise for timeouts. It usually doesn't make much sense to set it to a lower value than \f(CW0.01\fR, as this approsaches the timing granularity of most systems. .SH "ANATOMY OF A WATCHER" .IX Header "ANATOMY OF A WATCHER" A watcher is a structure that you create and register to record your interest in some event. For instance, if you want to wait for \s-1STDIN\s0 to become readable, you would create an \f(CW\*(C`ev_io\*(C'\fR watcher for that: .PP .Vb 5 \& static void my_cb (struct ev_loop *loop, struct ev_io *w, int revents) \& { \& ev_io_stop (w); \& ev_unloop (loop, EVUNLOOP_ALL); \& } .Ve .PP .Vb 6 \& struct ev_loop *loop = ev_default_loop (0); \& struct ev_io stdin_watcher; \& ev_init (&stdin_watcher, my_cb); \& ev_io_set (&stdin_watcher, STDIN_FILENO, EV_READ); \& ev_io_start (loop, &stdin_watcher); \& ev_loop (loop, 0); .Ve .PP As you can see, you are responsible for allocating the memory for your watcher structures (and it is usually a bad idea to do this on the stack, although this can sometimes be quite valid). .PP Each watcher structure must be initialised by a call to \f(CW\*(C`ev_init (watcher *, callback)\*(C'\fR, which expects a callback to be provided. This callback gets invoked each time the event occurs (or, in the case of io watchers, each time the event loop detects that the file descriptor given is readable and/or writable). .PP Each watcher type has its own \f(CW\*(C`ev_<type>_set (watcher *, ...)\*(C'\fR macro with arguments specific to this watcher type. There is also a macro to combine initialisation and setting in one call: \f(CW\*(C`ev_<type>_init (watcher *, callback, ...)\*(C'\fR. .PP To make the watcher actually watch out for events, you have to start it with a watcher-specific start function (\f(CW\*(C`ev_<type>_start (loop, watcher *)\*(C'\fR), and you can stop watching for events at any time by calling the corresponding stop function (\f(CW\*(C`ev_<type>_stop (loop, watcher *)\*(C'\fR. .PP As long as your watcher is active (has been started but not stopped) you must not touch the values stored in it. Most specifically you must never reinitialise it or call its \f(CW\*(C`set\*(C'\fR macro. .PP Each and every callback receives the event loop pointer as first, the registered watcher structure as second, and a bitset of received events as third argument. .PP The received events usually include a single bit per event type received (you can receive multiple events at the same time). The possible bit masks are: .ie n .IP """EV_READ""" 4 .el .IP "\f(CWEV_READ\fR" 4 .IX Item "EV_READ" .PD 0 .ie n .IP """EV_WRITE""" 4 .el .IP "\f(CWEV_WRITE\fR" 4 .IX Item "EV_WRITE" .PD The file descriptor in the \f(CW\*(C`ev_io\*(C'\fR watcher has become readable and/or writable. .ie n .IP """EV_TIMEOUT""" 4 .el .IP "\f(CWEV_TIMEOUT\fR" 4 .IX Item "EV_TIMEOUT" The \f(CW\*(C`ev_timer\*(C'\fR watcher has timed out. .ie n .IP """EV_PERIODIC""" 4 .el .IP "\f(CWEV_PERIODIC\fR" 4 .IX Item "EV_PERIODIC" The \f(CW\*(C`ev_periodic\*(C'\fR watcher has timed out. .ie n .IP """EV_SIGNAL""" 4 .el .IP "\f(CWEV_SIGNAL\fR" 4 .IX Item "EV_SIGNAL" The signal specified in the \f(CW\*(C`ev_signal\*(C'\fR watcher has been received by a thread. .ie n .IP """EV_CHILD""" 4 .el .IP "\f(CWEV_CHILD\fR" 4 .IX Item "EV_CHILD" The pid specified in the \f(CW\*(C`ev_child\*(C'\fR watcher has received a status change. .ie n .IP """EV_STAT""" 4 .el .IP "\f(CWEV_STAT\fR" 4 .IX Item "EV_STAT" The path specified in the \f(CW\*(C`ev_stat\*(C'\fR watcher changed its attributes somehow. .ie n .IP """EV_IDLE""" 4 .el .IP "\f(CWEV_IDLE\fR" 4 .IX Item "EV_IDLE" The \f(CW\*(C`ev_idle\*(C'\fR watcher has determined that you have nothing better to do. .ie n .IP """EV_PREPARE""" 4 .el .IP "\f(CWEV_PREPARE\fR" 4 .IX Item "EV_PREPARE" .PD 0 .ie n .IP """EV_CHECK""" 4 .el .IP "\f(CWEV_CHECK\fR" 4 .IX Item "EV_CHECK" .PD All \f(CW\*(C`ev_prepare\*(C'\fR watchers are invoked just \fIbefore\fR \f(CW\*(C`ev_loop\*(C'\fR starts to gather new events, and all \f(CW\*(C`ev_check\*(C'\fR watchers are invoked just after \&\f(CW\*(C`ev_loop\*(C'\fR has gathered them, but before it invokes any callbacks for any received events. Callbacks of both watcher types can start and stop as many watchers as they want, and all of them will be taken into account (for example, a \f(CW\*(C`ev_prepare\*(C'\fR watcher might start an idle watcher to keep \&\f(CW\*(C`ev_loop\*(C'\fR from blocking). .ie n .IP """EV_EMBED""" 4 .el .IP "\f(CWEV_EMBED\fR" 4 .IX Item "EV_EMBED" The embedded event loop specified in the \f(CW\*(C`ev_embed\*(C'\fR watcher needs attention. .ie n .IP """EV_FORK""" 4 .el .IP "\f(CWEV_FORK\fR" 4 .IX Item "EV_FORK" The event loop has been resumed in the child process after fork (see \&\f(CW\*(C`ev_fork\*(C'\fR). .ie n .IP """EV_ERROR""" 4 .el .IP "\f(CWEV_ERROR\fR" 4 .IX Item "EV_ERROR" An unspecified error has occured, the watcher has been stopped. This might happen because the watcher could not be properly started because libev ran out of memory, a file descriptor was found to be closed or any other problem. You best act on it by reporting the problem and somehow coping with the watcher being stopped. .Sp Libev will usually signal a few \*(L"dummy\*(R" events together with an error, for example it might indicate that a fd is readable or writable, and if your callbacks is well-written it can just attempt the operation and cope with the error from \fIread()\fR or \fIwrite()\fR. This will not work in multithreaded programs, though, so beware. .Sh "\s-1GENERIC\s0 \s-1WATCHER\s0 \s-1FUNCTIONS\s0" .IX Subsection "GENERIC WATCHER FUNCTIONS" In the following description, \f(CW\*(C`TYPE\*(C'\fR stands for the watcher type, e.g. \f(CW\*(C`timer\*(C'\fR for \f(CW\*(C`ev_timer\*(C'\fR watchers and \f(CW\*(C`io\*(C'\fR for \f(CW\*(C`ev_io\*(C'\fR watchers. .ie n .IP """ev_init"" (ev_TYPE *watcher, callback)" 4 .el .IP "\f(CWev_init\fR (ev_TYPE *watcher, callback)" 4 .IX Item "ev_init (ev_TYPE *watcher, callback)" This macro initialises the generic portion of a watcher. The contents of the watcher object can be arbitrary (so \f(CW\*(C`malloc\*(C'\fR will do). Only the generic parts of the watcher are initialised, you \fIneed\fR to call the type-specific \f(CW\*(C`ev_TYPE_set\*(C'\fR macro afterwards to initialise the type-specific parts. For each type there is also a \f(CW\*(C`ev_TYPE_init\*(C'\fR macro which rolls both calls into one. .Sp You can reinitialise a watcher at any time as long as it has been stopped (or never started) and there are no pending events outstanding. .Sp The callback is always of type \f(CW\*(C`void (*)(ev_loop *loop, ev_TYPE *watcher, int revents)\*(C'\fR. .ie n .IP """ev_TYPE_set"" (ev_TYPE *, [args])" 4 .el .IP "\f(CWev_TYPE_set\fR (ev_TYPE *, [args])" 4 .IX Item "ev_TYPE_set (ev_TYPE *, [args])" This macro initialises the type-specific parts of a watcher. You need to call \f(CW\*(C`ev_init\*(C'\fR at least once before you call this macro, but you can call \f(CW\*(C`ev_TYPE_set\*(C'\fR any number of times. You must not, however, call this macro on a watcher that is active (it can be pending, however, which is a difference to the \f(CW\*(C`ev_init\*(C'\fR macro). .Sp Although some watcher types do not have type-specific arguments (e.g. \f(CW\*(C`ev_prepare\*(C'\fR) you still need to call its \f(CW\*(C`set\*(C'\fR macro. .ie n .IP """ev_TYPE_init"" (ev_TYPE *watcher, callback, [args])" 4 .el .IP "\f(CWev_TYPE_init\fR (ev_TYPE *watcher, callback, [args])" 4 .IX Item "ev_TYPE_init (ev_TYPE *watcher, callback, [args])" This convinience macro rolls both \f(CW\*(C`ev_init\*(C'\fR and \f(CW\*(C`ev_TYPE_set\*(C'\fR macro calls into a single call. This is the most convinient method to initialise a watcher. The same limitations apply, of course. .ie n .IP """ev_TYPE_start"" (loop *, ev_TYPE *watcher)" 4 .el .IP "\f(CWev_TYPE_start\fR (loop *, ev_TYPE *watcher)" 4 .IX Item "ev_TYPE_start (loop *, ev_TYPE *watcher)" Starts (activates) the given watcher. Only active watchers will receive events. If the watcher is already active nothing will happen. .ie n .IP """ev_TYPE_stop"" (loop *, ev_TYPE *watcher)" 4 .el .IP "\f(CWev_TYPE_stop\fR (loop *, ev_TYPE *watcher)" 4 .IX Item "ev_TYPE_stop (loop *, ev_TYPE *watcher)" Stops the given watcher again (if active) and clears the pending status. It is possible that stopped watchers are pending (for example, non-repeating timers are being stopped when they become pending), but \&\f(CW\*(C`ev_TYPE_stop\*(C'\fR ensures that the watcher is neither active nor pending. If you want to free or reuse the memory used by the watcher it is therefore a good idea to always call its \f(CW\*(C`ev_TYPE_stop\*(C'\fR function. .IP "bool ev_is_active (ev_TYPE *watcher)" 4 .IX Item "bool ev_is_active (ev_TYPE *watcher)" Returns a true value iff the watcher is active (i.e. it has been started and not yet been stopped). As long as a watcher is active you must not modify it. .IP "bool ev_is_pending (ev_TYPE *watcher)" 4 .IX Item "bool ev_is_pending (ev_TYPE *watcher)" Returns a true value iff the watcher is pending, (i.e. it has outstanding events but its callback has not yet been invoked). As long as a watcher is pending (but not active) you must not call an init function on it (but \&\f(CW\*(C`ev_TYPE_set\*(C'\fR is safe), you must not change its priority, and you must make sure the watcher is available to libev (e.g. you cannot \f(CW\*(C`free ()\*(C'\fR it). .IP "callback ev_cb (ev_TYPE *watcher)" 4 .IX Item "callback ev_cb (ev_TYPE *watcher)" Returns the callback currently set on the watcher. .IP "ev_cb_set (ev_TYPE *watcher, callback)" 4 .IX Item "ev_cb_set (ev_TYPE *watcher, callback)" Change the callback. You can change the callback at virtually any time (modulo threads). .IP "ev_set_priority (ev_TYPE *watcher, priority)" 4 .IX Item "ev_set_priority (ev_TYPE *watcher, priority)" .PD 0 .IP "int ev_priority (ev_TYPE *watcher)" 4 .IX Item "int ev_priority (ev_TYPE *watcher)" .PD Set and query the priority of the watcher. The priority is a small integer between \f(CW\*(C`EV_MAXPRI\*(C'\fR (default: \f(CW2\fR) and \f(CW\*(C`EV_MINPRI\*(C'\fR (default: \f(CW\*(C`\-2\*(C'\fR). Pending watchers with higher priority will be invoked before watchers with lower priority, but priority will not keep watchers from being executed (except for \f(CW\*(C`ev_idle\*(C'\fR watchers). .Sp This means that priorities are \fIonly\fR used for ordering callback invocation after new events have been received. This is useful, for example, to reduce latency after idling, or more often, to bind two watchers on the same event and make sure one is called first. .Sp If you need to suppress invocation when higher priority events are pending you need to look at \f(CW\*(C`ev_idle\*(C'\fR watchers, which provide this functionality. .Sp You \fImust not\fR change the priority of a watcher as long as it is active or pending. .Sp The default priority used by watchers when no priority has been set is always \f(CW0\fR, which is supposed to not be too high and not be too low :). .Sp Setting a priority outside the range of \f(CW\*(C`EV_MINPRI\*(C'\fR to \f(CW\*(C`EV_MAXPRI\*(C'\fR is fine, as long as you do not mind that the priority value you query might or might not have been adjusted to be within valid range. .IP "ev_invoke (loop, ev_TYPE *watcher, int revents)" 4 .IX Item "ev_invoke (loop, ev_TYPE *watcher, int revents)" Invoke the \f(CW\*(C`watcher\*(C'\fR with the given \f(CW\*(C`loop\*(C'\fR and \f(CW\*(C`revents\*(C'\fR. Neither \&\f(CW\*(C`loop\*(C'\fR nor \f(CW\*(C`revents\*(C'\fR need to be valid as long as the watcher callback can deal with that fact. .IP "int ev_clear_pending (loop, ev_TYPE *watcher)" 4 .IX Item "int ev_clear_pending (loop, ev_TYPE *watcher)" If the watcher is pending, this function returns clears its pending status and returns its \f(CW\*(C`revents\*(C'\fR bitset (as if its callback was invoked). If the watcher isn't pending it does nothing and returns \f(CW0\fR. .Sh "\s-1ASSOCIATING\s0 \s-1CUSTOM\s0 \s-1DATA\s0 \s-1WITH\s0 A \s-1WATCHER\s0" .IX Subsection "ASSOCIATING CUSTOM DATA WITH A WATCHER" Each watcher has, by default, a member \f(CW\*(C`void *data\*(C'\fR that you can change and read at any time, libev will completely ignore it. This can be used to associate arbitrary data with your watcher. If you need more data and don't want to allocate memory and store a pointer to it in that data member, you can also \*(L"subclass\*(R" the watcher type and provide your own data: .PP .Vb 7 \& struct my_io \& { \& struct ev_io io; \& int otherfd; \& void *somedata; \& struct whatever *mostinteresting; \& } .Ve .PP And since your callback will be called with a pointer to the watcher, you can cast it back to your own type: .PP .Vb 5 \& static void my_cb (struct ev_loop *loop, struct ev_io *w_, int revents) \& { \& struct my_io *w = (struct my_io *)w_; \& ... \& } .Ve .PP More interesting and less C\-conformant ways of casting your callback type instead have been omitted. .PP Another common scenario is having some data structure with multiple watchers: .PP .Vb 6 \& struct my_biggy \& { \& int some_data; \& ev_timer t1; \& ev_timer t2; \& } .Ve .PP In this case getting the pointer to \f(CW\*(C`my_biggy\*(C'\fR is a bit more complicated, you need to use \f(CW\*(C`offsetof\*(C'\fR: .PP .Vb 1 \& #include <stddef.h> .Ve .PP .Vb 6 \& static void \& t1_cb (EV_P_ struct ev_timer *w, int revents) \& { \& struct my_biggy big = (struct my_biggy * \& (((char *)w) - offsetof (struct my_biggy, t1)); \& } .Ve .PP .Vb 6 \& static void \& t2_cb (EV_P_ struct ev_timer *w, int revents) \& { \& struct my_biggy big = (struct my_biggy * \& (((char *)w) - offsetof (struct my_biggy, t2)); \& } .Ve .SH "WATCHER TYPES" .IX Header "WATCHER TYPES" This section describes each watcher in detail, but will not repeat information given in the last section. Any initialisation/set macros, functions and members specific to the watcher type are explained. .PP Members are additionally marked with either \fI[read\-only]\fR, meaning that, while the watcher is active, you can look at the member and expect some sensible content, but you must not modify it (you can modify it while the watcher is stopped to your hearts content), or \fI[read\-write]\fR, which means you can expect it to have some sensible content while the watcher is active, but you can also modify it. Modifying it may not do something sensible or take immediate effect (or do anything at all), but libev will not crash or malfunction in any way. .ie n .Sh """ev_io"" \- is this file descriptor readable or writable?" .el .Sh "\f(CWev_io\fP \- is this file descriptor readable or writable?" .IX Subsection "ev_io - is this file descriptor readable or writable?" I/O watchers check whether a file descriptor is readable or writable in each iteration of the event loop, or, more precisely, when reading would not block the process and writing would at least be able to write some data. This behaviour is called level-triggering because you keep receiving events as long as the condition persists. Remember you can stop the watcher if you don't want to act on the event and neither want to receive future events. .PP In general you can register as many read and/or write event watchers per fd as you want (as long as you don't confuse yourself). Setting all file descriptors to non-blocking mode is also usually a good idea (but not required if you know what you are doing). .PP If you must do this, then force the use of a known-to-be-good backend (at the time of this writing, this includes only \f(CW\*(C`EVBACKEND_SELECT\*(C'\fR and \&\f(CW\*(C`EVBACKEND_POLL\*(C'\fR). .PP Another thing you have to watch out for is that it is quite easy to receive \*(L"spurious\*(R" readyness notifications, that is your callback might be called with \f(CW\*(C`EV_READ\*(C'\fR but a subsequent \f(CW\*(C`read\*(C'\fR(2) will actually block because there is no data. Not only are some backends known to create a lot of those (for example solaris ports), it is very easy to get into this situation even with a relatively standard program structure. Thus it is best to always use non-blocking I/O: An extra \f(CW\*(C`read\*(C'\fR(2) returning \&\f(CW\*(C`EAGAIN\*(C'\fR is far preferable to a program hanging until some data arrives. .PP If you cannot run the fd in non-blocking mode (for example you should not play around with an Xlib connection), then you have to seperately re-test whether a file descriptor is really ready with a known-to-be good interface such as poll (fortunately in our Xlib example, Xlib already does this on its own, so its quite safe to use). .PP \fIThe special problem of disappearing file descriptors\fR .IX Subsection "The special problem of disappearing file descriptors" .PP Some backends (e.g. kqueue, epoll) need to be told about closing a file descriptor (either by calling \f(CW\*(C`close\*(C'\fR explicitly or by any other means, such as \f(CW\*(C`dup\*(C'\fR). The reason is that you register interest in some file descriptor, but when it goes away, the operating system will silently drop this interest. If another file descriptor with the same number then is registered with libev, there is no efficient way to see that this is, in fact, a different file descriptor. .PP To avoid having to explicitly tell libev about such cases, libev follows the following policy: Each time \f(CW\*(C`ev_io_set\*(C'\fR is being called, libev will assume that this is potentially a new file descriptor, otherwise it is assumed that the file descriptor stays the same. That means that you \fIhave\fR to call \f(CW\*(C`ev_io_set\*(C'\fR (or \f(CW\*(C`ev_io_init\*(C'\fR) when you change the descriptor even if the file descriptor number itself did not change. .PP This is how one would do it normally anyway, the important point is that the libev application should not optimise around libev but should leave optimisations to libev. .PP \fIThe special problem of dup'ed file descriptors\fR .IX Subsection "The special problem of dup'ed file descriptors" .PP Some backends (e.g. epoll), cannot register events for file descriptors, but only events for the underlying file descriptions. That means when you have \f(CW\*(C`dup ()\*(C'\fR'ed file descriptors or weirder constellations, and register events for them, only one file descriptor might actually receive events. .PP There is no workaround possible except not registering events for potentially \f(CW\*(C`dup ()\*(C'\fR'ed file descriptors, or to resort to \&\f(CW\*(C`EVBACKEND_SELECT\*(C'\fR or \f(CW\*(C`EVBACKEND_POLL\*(C'\fR. .PP \fIThe special problem of fork\fR .IX Subsection "The special problem of fork" .PP Some backends (epoll, kqueue) do not support \f(CW\*(C`fork ()\*(C'\fR at all or exhibit useless behaviour. Libev fully supports fork, but needs to be told about it in the child. .PP To support fork in your programs, you either have to call \&\f(CW\*(C`ev_default_fork ()\*(C'\fR or \f(CW\*(C`ev_loop_fork ()\*(C'\fR after a fork in the child, enable \f(CW\*(C`EVFLAG_FORKCHECK\*(C'\fR, or resort to \f(CW\*(C`EVBACKEND_SELECT\*(C'\fR or \&\f(CW\*(C`EVBACKEND_POLL\*(C'\fR. .PP \fIWatcher-Specific Functions\fR .IX Subsection "Watcher-Specific Functions" .IP "ev_io_init (ev_io *, callback, int fd, int events)" 4 .IX Item "ev_io_init (ev_io *, callback, int fd, int events)" .PD 0 .IP "ev_io_set (ev_io *, int fd, int events)" 4 .IX Item "ev_io_set (ev_io *, int fd, int events)" .PD Configures an \f(CW\*(C`ev_io\*(C'\fR watcher. The \f(CW\*(C`fd\*(C'\fR is the file descriptor to rceeive events for and events is either \f(CW\*(C`EV_READ\*(C'\fR, \f(CW\*(C`EV_WRITE\*(C'\fR or \&\f(CW\*(C`EV_READ | EV_WRITE\*(C'\fR to receive the given events. .IP "int fd [read\-only]" 4 .IX Item "int fd [read-only]" The file descriptor being watched. .IP "int events [read\-only]" 4 .IX Item "int events [read-only]" The events being watched. .PP Example: Call \f(CW\*(C`stdin_readable_cb\*(C'\fR when \s-1STDIN_FILENO\s0 has become, well readable, but only once. Since it is likely line\-buffered, you could attempt to read a whole line in the callback. .PP .Vb 6 \& static void \& stdin_readable_cb (struct ev_loop *loop, struct ev_io *w, int revents) \& { \& ev_io_stop (loop, w); \& .. read from stdin here (or from w->fd) and haqndle any I/O errors \& } .Ve .PP .Vb 6 \& ... \& struct ev_loop *loop = ev_default_init (0); \& struct ev_io stdin_readable; \& ev_io_init (&stdin_readable, stdin_readable_cb, STDIN_FILENO, EV_READ); \& ev_io_start (loop, &stdin_readable); \& ev_loop (loop, 0); .Ve .ie n .Sh """ev_timer"" \- relative and optionally repeating timeouts" .el .Sh "\f(CWev_timer\fP \- relative and optionally repeating timeouts" .IX Subsection "ev_timer - relative and optionally repeating timeouts" Timer watchers are simple relative timers that generate an event after a given time, and optionally repeating in regular intervals after that. .PP The timers are based on real time, that is, if you register an event that times out after an hour and you reset your system clock to last years time, it will still time out after (roughly) and hour. \*(L"Roughly\*(R" because detecting time jumps is hard, and some inaccuracies are unavoidable (the monotonic clock option helps a lot here). .PP The relative timeouts are calculated relative to the \f(CW\*(C`ev_now ()\*(C'\fR time. This is usually the right thing as this timestamp refers to the time of the event triggering whatever timeout you are modifying/starting. If you suspect event processing to be delayed and you \fIneed\fR to base the timeout on the current time, use something like this to adjust for this: .PP .Vb 1 \& ev_timer_set (&timer, after + ev_now () - ev_time (), 0.); .Ve .PP The callback is guarenteed to be invoked only when its timeout has passed, but if multiple timers become ready during the same loop iteration then order of execution is undefined. .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_timer_init (ev_timer *, callback, ev_tstamp after, ev_tstamp repeat)" 4 .IX Item "ev_timer_init (ev_timer *, callback, ev_tstamp after, ev_tstamp repeat)" .PD 0 .IP "ev_timer_set (ev_timer *, ev_tstamp after, ev_tstamp repeat)" 4 .IX Item "ev_timer_set (ev_timer *, ev_tstamp after, ev_tstamp repeat)" .PD Configure the timer to trigger after \f(CW\*(C`after\*(C'\fR seconds. If \f(CW\*(C`repeat\*(C'\fR is \&\f(CW0.\fR, then it will automatically be stopped. If it is positive, then the timer will automatically be configured to trigger again \f(CW\*(C`repeat\*(C'\fR seconds later, again, and again, until stopped manually. .Sp The timer itself will do a best-effort at avoiding drift, that is, if you configure a timer to trigger every 10 seconds, then it will trigger at exactly 10 second intervals. If, however, your program cannot keep up with the timer (because it takes longer than those 10 seconds to do stuff) the timer will not fire more than once per event loop iteration. .IP "ev_timer_again (loop)" 4 .IX Item "ev_timer_again (loop)" This will act as if the timer timed out and restart it again if it is repeating. The exact semantics are: .Sp If the timer is pending, its pending status is cleared. .Sp If the timer is started but nonrepeating, stop it (as if it timed out). .Sp If the timer is repeating, either start it if necessary (with the \&\f(CW\*(C`repeat\*(C'\fR value), or reset the running timer to the \f(CW\*(C`repeat\*(C'\fR value. .Sp This sounds a bit complicated, but here is a useful and typical example: Imagine you have a tcp connection and you want a so-called idle timeout, that is, you want to be called when there have been, say, 60 seconds of inactivity on the socket. The easiest way to do this is to configure an \f(CW\*(C`ev_timer\*(C'\fR with a \f(CW\*(C`repeat\*(C'\fR value of \f(CW60\fR and then call \&\f(CW\*(C`ev_timer_again\*(C'\fR each time you successfully read or write some data. If you go into an idle state where you do not expect data to travel on the socket, you can \f(CW\*(C`ev_timer_stop\*(C'\fR the timer, and \f(CW\*(C`ev_timer_again\*(C'\fR will automatically restart it if need be. .Sp That means you can ignore the \f(CW\*(C`after\*(C'\fR value and \f(CW\*(C`ev_timer_start\*(C'\fR altogether and only ever use the \f(CW\*(C`repeat\*(C'\fR value and \f(CW\*(C`ev_timer_again\*(C'\fR: .Sp .Vb 8 \& ev_timer_init (timer, callback, 0., 5.); \& ev_timer_again (loop, timer); \& ... \& timer->again = 17.; \& ev_timer_again (loop, timer); \& ... \& timer->again = 10.; \& ev_timer_again (loop, timer); .Ve .Sp This is more slightly efficient then stopping/starting the timer each time you want to modify its timeout value. .IP "ev_tstamp repeat [read\-write]" 4 .IX Item "ev_tstamp repeat [read-write]" The current \f(CW\*(C`repeat\*(C'\fR value. Will be used each time the watcher times out or \f(CW\*(C`ev_timer_again\*(C'\fR is called and determines the next timeout (if any), which is also when any modifications are taken into account. .PP Example: Create a timer that fires after 60 seconds. .PP .Vb 5 \& static void \& one_minute_cb (struct ev_loop *loop, struct ev_timer *w, int revents) \& { \& .. one minute over, w is actually stopped right here \& } .Ve .PP .Vb 3 \& struct ev_timer mytimer; \& ev_timer_init (&mytimer, one_minute_cb, 60., 0.); \& ev_timer_start (loop, &mytimer); .Ve .PP Example: Create a timeout timer that times out after 10 seconds of inactivity. .PP .Vb 5 \& static void \& timeout_cb (struct ev_loop *loop, struct ev_timer *w, int revents) \& { \& .. ten seconds without any activity \& } .Ve .PP .Vb 4 \& struct ev_timer mytimer; \& ev_timer_init (&mytimer, timeout_cb, 0., 10.); /* note, only repeat used */ \& ev_timer_again (&mytimer); /* start timer */ \& ev_loop (loop, 0); .Ve .PP .Vb 3 \& // and in some piece of code that gets executed on any "activity": \& // reset the timeout to start ticking again at 10 seconds \& ev_timer_again (&mytimer); .Ve .ie n .Sh """ev_periodic"" \- to cron or not to cron?" .el .Sh "\f(CWev_periodic\fP \- to cron or not to cron?" .IX Subsection "ev_periodic - to cron or not to cron?" Periodic watchers are also timers of a kind, but they are very versatile (and unfortunately a bit complex). .PP Unlike \f(CW\*(C`ev_timer\*(C'\fR's, they are not based on real time (or relative time) but on wallclock time (absolute time). You can tell a periodic watcher to trigger \*(L"at\*(R" some specific point in time. For example, if you tell a periodic watcher to trigger in 10 seconds (by specifiying e.g. \f(CW\*(C`ev_now () + 10.\*(C'\fR) and then reset your system clock to the last year, then it will take a year to trigger the event (unlike an \f(CW\*(C`ev_timer\*(C'\fR, which would trigger roughly 10 seconds later). .PP They can also be used to implement vastly more complex timers, such as triggering an event on each midnight, local time or other, complicated, rules. .PP As with timers, the callback is guarenteed to be invoked only when the time (\f(CW\*(C`at\*(C'\fR) has been passed, but if multiple periodic timers become ready during the same loop iteration then order of execution is undefined. .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_periodic_init (ev_periodic *, callback, ev_tstamp at, ev_tstamp interval, reschedule_cb)" 4 .IX Item "ev_periodic_init (ev_periodic *, callback, ev_tstamp at, ev_tstamp interval, reschedule_cb)" .PD 0 .IP "ev_periodic_set (ev_periodic *, ev_tstamp after, ev_tstamp repeat, reschedule_cb)" 4 .IX Item "ev_periodic_set (ev_periodic *, ev_tstamp after, ev_tstamp repeat, reschedule_cb)" .PD Lots of arguments, lets sort it out... There are basically three modes of operation, and we will explain them from simplest to complex: .RS 4 .IP "* absolute timer (at = time, interval = reschedule_cb = 0)" 4 .IX Item "absolute timer (at = time, interval = reschedule_cb = 0)" In this configuration the watcher triggers an event at the wallclock time \&\f(CW\*(C`at\*(C'\fR and doesn't repeat. It will not adjust when a time jump occurs, that is, if it is to be run at January 1st 2011 then it will run when the system time reaches or surpasses this time. .IP "* non-repeating interval timer (at = offset, interval > 0, reschedule_cb = 0)" 4 .IX Item "non-repeating interval timer (at = offset, interval > 0, reschedule_cb = 0)" In this mode the watcher will always be scheduled to time out at the next \&\f(CW\*(C`at + N * interval\*(C'\fR time (for some integer N, which can also be negative) and then repeat, regardless of any time jumps. .Sp This can be used to create timers that do not drift with respect to system time: .Sp .Vb 1 \& ev_periodic_set (&periodic, 0., 3600., 0); .Ve .Sp This doesn't mean there will always be 3600 seconds in between triggers, but only that the the callback will be called when the system time shows a full hour (\s-1UTC\s0), or more correctly, when the system time is evenly divisible by 3600. .Sp Another way to think about it (for the mathematically inclined) is that \&\f(CW\*(C`ev_periodic\*(C'\fR will try to run the callback in this mode at the next possible time where \f(CW\*(C`time = at (mod interval)\*(C'\fR, regardless of any time jumps. .Sp For numerical stability it is preferable that the \f(CW\*(C`at\*(C'\fR value is near \&\f(CW\*(C`ev_now ()\*(C'\fR (the current time), but there is no range requirement for this value. .IP "* manual reschedule mode (at and interval ignored, reschedule_cb = callback)" 4 .IX Item "manual reschedule mode (at and interval ignored, reschedule_cb = callback)" In this mode the values for \f(CW\*(C`interval\*(C'\fR and \f(CW\*(C`at\*(C'\fR are both being ignored. Instead, each time the periodic watcher gets scheduled, the reschedule callback will be called with the watcher as first, and the current time as second argument. .Sp \&\s-1NOTE:\s0 \fIThis callback \s-1MUST\s0 \s-1NOT\s0 stop or destroy any periodic watcher, ever, or make any event loop modifications\fR. If you need to stop it, return \f(CW\*(C`now + 1e30\*(C'\fR (or so, fudge fudge) and stop it afterwards (e.g. by starting an \f(CW\*(C`ev_prepare\*(C'\fR watcher, which is legal). .Sp Its prototype is \f(CW\*(C`ev_tstamp (*reschedule_cb)(struct ev_periodic *w, ev_tstamp now)\*(C'\fR, e.g.: .Sp .Vb 4 \& static ev_tstamp my_rescheduler (struct ev_periodic *w, ev_tstamp now) \& { \& return now + 60.; \& } .Ve .Sp It must return the next time to trigger, based on the passed time value (that is, the lowest time value larger than to the second argument). It will usually be called just before the callback will be triggered, but might be called at other times, too. .Sp \&\s-1NOTE:\s0 \fIThis callback must always return a time that is later than the passed \f(CI\*(C`now\*(C'\fI value\fR. Not even \f(CW\*(C`now\*(C'\fR itself will do, it \fImust\fR be larger. .Sp This can be used to create very complex timers, such as a timer that triggers on each midnight, local time. To do this, you would calculate the next midnight after \f(CW\*(C`now\*(C'\fR and return the timestamp value for this. How you do this is, again, up to you (but it is not trivial, which is the main reason I omitted it as an example). .RE .RS 4 .RE .IP "ev_periodic_again (loop, ev_periodic *)" 4 .IX Item "ev_periodic_again (loop, ev_periodic *)" Simply stops and restarts the periodic watcher again. This is only useful when you changed some parameters or the reschedule callback would return a different time than the last time it was called (e.g. in a crond like program when the crontabs have changed). .IP "ev_tstamp offset [read\-write]" 4 .IX Item "ev_tstamp offset [read-write]" When repeating, this contains the offset value, otherwise this is the absolute point in time (the \f(CW\*(C`at\*(C'\fR value passed to \f(CW\*(C`ev_periodic_set\*(C'\fR). .Sp Can be modified any time, but changes only take effect when the periodic timer fires or \f(CW\*(C`ev_periodic_again\*(C'\fR is being called. .IP "ev_tstamp interval [read\-write]" 4 .IX Item "ev_tstamp interval [read-write]" The current interval value. Can be modified any time, but changes only take effect when the periodic timer fires or \f(CW\*(C`ev_periodic_again\*(C'\fR is being called. .IP "ev_tstamp (*reschedule_cb)(struct ev_periodic *w, ev_tstamp now) [read\-write]" 4 .IX Item "ev_tstamp (*reschedule_cb)(struct ev_periodic *w, ev_tstamp now) [read-write]" The current reschedule callback, or \f(CW0\fR, if this functionality is switched off. Can be changed any time, but changes only take effect when the periodic timer fires or \f(CW\*(C`ev_periodic_again\*(C'\fR is being called. .IP "ev_tstamp at [read\-only]" 4 .IX Item "ev_tstamp at [read-only]" When active, contains the absolute time that the watcher is supposed to trigger next. .PP Example: Call a callback every hour, or, more precisely, whenever the system clock is divisible by 3600. The callback invocation times have potentially a lot of jittering, but good long-term stability. .PP .Vb 5 \& static void \& clock_cb (struct ev_loop *loop, struct ev_io *w, int revents) \& { \& ... its now a full hour (UTC, or TAI or whatever your clock follows) \& } .Ve .PP .Vb 3 \& struct ev_periodic hourly_tick; \& ev_periodic_init (&hourly_tick, clock_cb, 0., 3600., 0); \& ev_periodic_start (loop, &hourly_tick); .Ve .PP Example: The same as above, but use a reschedule callback to do it: .PP .Vb 1 \& #include <math.h> .Ve .PP .Vb 5 \& static ev_tstamp \& my_scheduler_cb (struct ev_periodic *w, ev_tstamp now) \& { \& return fmod (now, 3600.) + 3600.; \& } .Ve .PP .Vb 1 \& ev_periodic_init (&hourly_tick, clock_cb, 0., 0., my_scheduler_cb); .Ve .PP Example: Call a callback every hour, starting now: .PP .Vb 4 \& struct ev_periodic hourly_tick; \& ev_periodic_init (&hourly_tick, clock_cb, \& fmod (ev_now (loop), 3600.), 3600., 0); \& ev_periodic_start (loop, &hourly_tick); .Ve .ie n .Sh """ev_signal"" \- signal me when a signal gets signalled!" .el .Sh "\f(CWev_signal\fP \- signal me when a signal gets signalled!" .IX Subsection "ev_signal - signal me when a signal gets signalled!" Signal watchers will trigger an event when the process receives a specific signal one or more times. Even though signals are very asynchronous, libev will try it's best to deliver signals synchronously, i.e. as part of the normal event processing, like any other event. .PP You can configure as many watchers as you like per signal. Only when the first watcher gets started will libev actually register a signal watcher with the kernel (thus it coexists with your own signal handlers as long as you don't register any with libev). Similarly, when the last signal watcher for a signal is stopped libev will reset the signal handler to \&\s-1SIG_DFL\s0 (regardless of what it was set to before). .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_signal_init (ev_signal *, callback, int signum)" 4 .IX Item "ev_signal_init (ev_signal *, callback, int signum)" .PD 0 .IP "ev_signal_set (ev_signal *, int signum)" 4 .IX Item "ev_signal_set (ev_signal *, int signum)" .PD Configures the watcher to trigger on the given signal number (usually one of the \f(CW\*(C`SIGxxx\*(C'\fR constants). .IP "int signum [read\-only]" 4 .IX Item "int signum [read-only]" The signal the watcher watches out for. .ie n .Sh """ev_child"" \- watch out for process status changes" .el .Sh "\f(CWev_child\fP \- watch out for process status changes" .IX Subsection "ev_child - watch out for process status changes" Child watchers trigger when your process receives a \s-1SIGCHLD\s0 in response to some child status changes (most typically when a child of yours dies). .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_child_init (ev_child *, callback, int pid)" 4 .IX Item "ev_child_init (ev_child *, callback, int pid)" .PD 0 .IP "ev_child_set (ev_child *, int pid)" 4 .IX Item "ev_child_set (ev_child *, int pid)" .PD Configures the watcher to wait for status changes of process \f(CW\*(C`pid\*(C'\fR (or \&\fIany\fR process if \f(CW\*(C`pid\*(C'\fR is specified as \f(CW0\fR). The callback can look at the \f(CW\*(C`rstatus\*(C'\fR member of the \f(CW\*(C`ev_child\*(C'\fR watcher structure to see the status word (use the macros from \f(CW\*(C`sys/wait.h\*(C'\fR and see your systems \&\f(CW\*(C`waitpid\*(C'\fR documentation). The \f(CW\*(C`rpid\*(C'\fR member contains the pid of the process causing the status change. .IP "int pid [read\-only]" 4 .IX Item "int pid [read-only]" The process id this watcher watches out for, or \f(CW0\fR, meaning any process id. .IP "int rpid [read\-write]" 4 .IX Item "int rpid [read-write]" The process id that detected a status change. .IP "int rstatus [read\-write]" 4 .IX Item "int rstatus [read-write]" The process exit/trace status caused by \f(CW\*(C`rpid\*(C'\fR (see your systems \&\f(CW\*(C`waitpid\*(C'\fR and \f(CW\*(C`sys/wait.h\*(C'\fR documentation for details). .PP Example: Try to exit cleanly on \s-1SIGINT\s0 and \s-1SIGTERM\s0. .PP .Vb 5 \& static void \& sigint_cb (struct ev_loop *loop, struct ev_signal *w, int revents) \& { \& ev_unloop (loop, EVUNLOOP_ALL); \& } .Ve .PP .Vb 3 \& struct ev_signal signal_watcher; \& ev_signal_init (&signal_watcher, sigint_cb, SIGINT); \& ev_signal_start (loop, &sigint_cb); .Ve .ie n .Sh """ev_stat"" \- did the file attributes just change?" .el .Sh "\f(CWev_stat\fP \- did the file attributes just change?" .IX Subsection "ev_stat - did the file attributes just change?" This watches a filesystem path for attribute changes. That is, it calls \&\f(CW\*(C`stat\*(C'\fR regularly (or when the \s-1OS\s0 says it changed) and sees if it changed compared to the last time, invoking the callback if it did. .PP The path does not need to exist: changing from \*(L"path exists\*(R" to \*(L"path does not exist\*(R" is a status change like any other. The condition \*(L"path does not exist\*(R" is signified by the \f(CW\*(C`st_nlink\*(C'\fR field being zero (which is otherwise always forced to be at least one) and all the other fields of the stat buffer having unspecified contents. .PP The path \fIshould\fR be absolute and \fImust not\fR end in a slash. If it is relative and your working directory changes, the behaviour is undefined. .PP Since there is no standard to do this, the portable implementation simply calls \f(CW\*(C`stat (2)\*(C'\fR regularly on the path to see if it changed somehow. You can specify a recommended polling interval for this case. If you specify a polling interval of \f(CW0\fR (highly recommended!) then a \fIsuitable, unspecified default\fR value will be used (which you can expect to be around five seconds, although this might change dynamically). Libev will also impose a minimum interval which is currently around \f(CW0.1\fR, but thats usually overkill. .PP This watcher type is not meant for massive numbers of stat watchers, as even with OS-supported change notifications, this can be resource\-intensive. .PP At the time of this writing, only the Linux inotify interface is implemented (implementing kqueue support is left as an exercise for the reader). Inotify will be used to give hints only and should not change the semantics of \f(CW\*(C`ev_stat\*(C'\fR watchers, which means that libev sometimes needs to fall back to regular polling again even with inotify, but changes are usually detected immediately, and if the file exists there will be no polling. .PP \fIInotify\fR .IX Subsection "Inotify" .PP When \f(CW\*(C`inotify (7)\*(C'\fR support has been compiled into libev (generally only available on Linux) and present at runtime, it will be used to speed up change detection where possible. The inotify descriptor will be created lazily when the first \f(CW\*(C`ev_stat\*(C'\fR watcher is being started. .PP Inotify presense does not change the semantics of \f(CW\*(C`ev_stat\*(C'\fR watchers except that changes might be detected earlier, and in some cases, to avoid making regular \f(CW\*(C`stat\*(C'\fR calls. Even in the presense of inotify support there are many cases where libev has to resort to regular \f(CW\*(C`stat\*(C'\fR polling. .PP (There is no support for kqueue, as apparently it cannot be used to implement this functionality, due to the requirement of having a file descriptor open on the object at all times). .PP \fIThe special problem of stat time resolution\fR .IX Subsection "The special problem of stat time resolution" .PP The \f(CW\*(C`stat ()\*(C'\fR syscall only supports full-second resolution portably, and even on systems where the resolution is higher, many filesystems still only support whole seconds. .PP That means that, if the time is the only thing that changes, you might miss updates: on the first update, \f(CW\*(C`ev_stat\*(C'\fR detects a change and calls your callback, which does something. When there is another update within the same second, \f(CW\*(C`ev_stat\*(C'\fR will be unable to detect it. .PP The solution to this is to delay acting on a change for a second (or till the next second boundary), using a roughly one-second delay \f(CW\*(C`ev_timer\*(C'\fR (\f(CW\*(C`ev_timer_set (w, 0., 1.01); ev_timer_again (loop, w)\*(C'\fR). The \f(CW.01\fR is added to work around small timing inconsistencies of some operating systems. .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_stat_init (ev_stat *, callback, const char *path, ev_tstamp interval)" 4 .IX Item "ev_stat_init (ev_stat *, callback, const char *path, ev_tstamp interval)" .PD 0 .IP "ev_stat_set (ev_stat *, const char *path, ev_tstamp interval)" 4 .IX Item "ev_stat_set (ev_stat *, const char *path, ev_tstamp interval)" .PD Configures the watcher to wait for status changes of the given \&\f(CW\*(C`path\*(C'\fR. The \f(CW\*(C`interval\*(C'\fR is a hint on how quickly a change is expected to be detected and should normally be specified as \f(CW0\fR to let libev choose a suitable value. The memory pointed to by \f(CW\*(C`path\*(C'\fR must point to the same path for as long as the watcher is active. .Sp The callback will be receive \f(CW\*(C`EV_STAT\*(C'\fR when a change was detected, relative to the attributes at the time the watcher was started (or the last change was detected). .IP "ev_stat_stat (ev_stat *)" 4 .IX Item "ev_stat_stat (ev_stat *)" Updates the stat buffer immediately with new values. If you change the watched path in your callback, you could call this fucntion to avoid detecting this change (while introducing a race condition). Can also be useful simply to find out the new values. .IP "ev_statdata attr [read\-only]" 4 .IX Item "ev_statdata attr [read-only]" The most-recently detected attributes of the file. Although the type is of \&\f(CW\*(C`ev_statdata\*(C'\fR, this is usually the (or one of the) \f(CW\*(C`struct stat\*(C'\fR types suitable for your system. If the \f(CW\*(C`st_nlink\*(C'\fR member is \f(CW0\fR, then there was some error while \f(CW\*(C`stat\*(C'\fRing the file. .IP "ev_statdata prev [read\-only]" 4 .IX Item "ev_statdata prev [read-only]" The previous attributes of the file. The callback gets invoked whenever \&\f(CW\*(C`prev\*(C'\fR != \f(CW\*(C`attr\*(C'\fR. .IP "ev_tstamp interval [read\-only]" 4 .IX Item "ev_tstamp interval [read-only]" The specified interval. .IP "const char *path [read\-only]" 4 .IX Item "const char *path [read-only]" The filesystem path that is being watched. .PP \fIExamples\fR .IX Subsection "Examples" .PP Example: Watch \f(CW\*(C`/etc/passwd\*(C'\fR for attribute changes. .PP .Vb 15 \& static void \& passwd_cb (struct ev_loop *loop, ev_stat *w, int revents) \& { \& /* /etc/passwd changed in some way */ \& if (w->attr.st_nlink) \& { \& printf ("passwd current size %ld\en", (long)w->attr.st_size); \& printf ("passwd current atime %ld\en", (long)w->attr.st_mtime); \& printf ("passwd current mtime %ld\en", (long)w->attr.st_mtime); \& } \& else \& /* you shalt not abuse printf for puts */ \& puts ("wow, /etc/passwd is not there, expect problems. " \& "if this is windows, they already arrived\en"); \& } .Ve .PP .Vb 2 \& ... \& ev_stat passwd; .Ve .PP .Vb 2 \& ev_stat_init (&passwd, passwd_cb, "/etc/passwd", 0.); \& ev_stat_start (loop, &passwd); .Ve .PP Example: Like above, but additionally use a one-second delay so we do not miss updates (however, frequent updates will delay processing, too, so one might do the work both on \f(CW\*(C`ev_stat\*(C'\fR callback invocation \fIand\fR on \&\f(CW\*(C`ev_timer\*(C'\fR callback invocation). .PP .Vb 2 \& static ev_stat passwd; \& static ev_timer timer; .Ve .PP .Vb 4 \& static void \& timer_cb (EV_P_ ev_timer *w, int revents) \& { \& ev_timer_stop (EV_A_ w); .Ve .PP .Vb 2 \& /* now it's one second after the most recent passwd change */ \& } .Ve .PP .Vb 6 \& static void \& stat_cb (EV_P_ ev_stat *w, int revents) \& { \& /* reset the one-second timer */ \& ev_timer_again (EV_A_ &timer); \& } .Ve .PP .Vb 4 \& ... \& ev_stat_init (&passwd, stat_cb, "/etc/passwd", 0.); \& ev_stat_start (loop, &passwd); \& ev_timer_init (&timer, timer_cb, 0., 1.01); .Ve .ie n .Sh """ev_idle"" \- when you've got nothing better to do..." .el .Sh "\f(CWev_idle\fP \- when you've got nothing better to do..." .IX Subsection "ev_idle - when you've got nothing better to do..." Idle watchers trigger events when no other events of the same or higher priority are pending (prepare, check and other idle watchers do not count). .PP That is, as long as your process is busy handling sockets or timeouts (or even signals, imagine) of the same or higher priority it will not be triggered. But when your process is idle (or only lower-priority watchers are pending), the idle watchers are being called once per event loop iteration \- until stopped, that is, or your process receives more events and becomes busy again with higher priority stuff. .PP The most noteworthy effect is that as long as any idle watchers are active, the process will not block when waiting for new events. .PP Apart from keeping your process non-blocking (which is a useful effect on its own sometimes), idle watchers are a good place to do \&\*(L"pseudo\-background processing\*(R", or delay processing stuff to after the event loop has handled all outstanding events. .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_idle_init (ev_signal *, callback)" 4 .IX Item "ev_idle_init (ev_signal *, callback)" Initialises and configures the idle watcher \- it has no parameters of any kind. There is a \f(CW\*(C`ev_idle_set\*(C'\fR macro, but using it is utterly pointless, believe me. .PP Example: Dynamically allocate an \f(CW\*(C`ev_idle\*(C'\fR watcher, start it, and in the callback, free it. Also, use no error checking, as usual. .PP .Vb 7 \& static void \& idle_cb (struct ev_loop *loop, struct ev_idle *w, int revents) \& { \& free (w); \& // now do something you wanted to do when the program has \& // no longer asnything immediate to do. \& } .Ve .PP .Vb 3 \& struct ev_idle *idle_watcher = malloc (sizeof (struct ev_idle)); \& ev_idle_init (idle_watcher, idle_cb); \& ev_idle_start (loop, idle_cb); .Ve .ie n .Sh """ev_prepare""\fP and \f(CW""ev_check"" \- customise your event loop!" .el .Sh "\f(CWev_prepare\fP and \f(CWev_check\fP \- customise your event loop!" .IX Subsection "ev_prepare and ev_check - customise your event loop!" Prepare and check watchers are usually (but not always) used in tandem: prepare watchers get invoked before the process blocks and check watchers afterwards. .PP You \fImust not\fR call \f(CW\*(C`ev_loop\*(C'\fR or similar functions that enter the current event loop from either \f(CW\*(C`ev_prepare\*(C'\fR or \f(CW\*(C`ev_check\*(C'\fR watchers. Other loops than the current one are fine, however. The rationale behind this is that you do not need to check for recursion in those watchers, i.e. the sequence will always be \f(CW\*(C`ev_prepare\*(C'\fR, blocking, \&\f(CW\*(C`ev_check\*(C'\fR so if you have one watcher of each kind they will always be called in pairs bracketing the blocking call. .PP Their main purpose is to integrate other event mechanisms into libev and their use is somewhat advanced. This could be used, for example, to track variable changes, implement your own watchers, integrate net-snmp or a coroutine library and lots more. They are also occasionally useful if you cache some data and want to flush it before blocking (for example, in X programs you might want to do an \f(CW\*(C`XFlush ()\*(C'\fR in an \f(CW\*(C`ev_prepare\*(C'\fR watcher). .PP This is done by examining in each prepare call which file descriptors need to be watched by the other library, registering \f(CW\*(C`ev_io\*(C'\fR watchers for them and starting an \f(CW\*(C`ev_timer\*(C'\fR watcher for any timeouts (many libraries provide just this functionality). Then, in the check watcher you check for any events that occured (by checking the pending status of all watchers and stopping them) and call back into the library. The I/O and timer callbacks will never actually be called (but must be valid nevertheless, because you never know, you know?). .PP As another example, the Perl Coro module uses these hooks to integrate coroutines into libev programs, by yielding to other active coroutines during each prepare and only letting the process block if no coroutines are ready to run (it's actually more complicated: it only runs coroutines with priority higher than or equal to the event loop and one coroutine of lower priority, but only once, using idle watchers to keep the event loop from blocking if lower-priority coroutines are active, thus mapping low-priority coroutines to idle/background tasks). .PP It is recommended to give \f(CW\*(C`ev_check\*(C'\fR watchers highest (\f(CW\*(C`EV_MAXPRI\*(C'\fR) priority, to ensure that they are being run before any other watchers after the poll. Also, \f(CW\*(C`ev_check\*(C'\fR watchers (and \f(CW\*(C`ev_prepare\*(C'\fR watchers, too) should not activate (\*(L"feed\*(R") events into libev. While libev fully supports this, they will be called before other \f(CW\*(C`ev_check\*(C'\fR watchers did their job. As \f(CW\*(C`ev_check\*(C'\fR watchers are often used to embed other (non\-libev) event loops those other event loops might be in an unusable state until their \f(CW\*(C`ev_check\*(C'\fR watcher ran (always remind yourself to coexist peacefully with others). .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_prepare_init (ev_prepare *, callback)" 4 .IX Item "ev_prepare_init (ev_prepare *, callback)" .PD 0 .IP "ev_check_init (ev_check *, callback)" 4 .IX Item "ev_check_init (ev_check *, callback)" .PD Initialises and configures the prepare or check watcher \- they have no parameters of any kind. There are \f(CW\*(C`ev_prepare_set\*(C'\fR and \f(CW\*(C`ev_check_set\*(C'\fR macros, but using them is utterly, utterly and completely pointless. .PP There are a number of principal ways to embed other event loops or modules into libev. Here are some ideas on how to include libadns into libev (there is a Perl module named \f(CW\*(C`EV::ADNS\*(C'\fR that does this, which you could use for an actually working example. Another Perl module named \f(CW\*(C`EV::Glib\*(C'\fR embeds a Glib main context into libev, and finally, \f(CW\*(C`Glib::EV\*(C'\fR embeds \s-1EV\s0 into the Glib event loop). .PP Method 1: Add \s-1IO\s0 watchers and a timeout watcher in a prepare handler, and in a check watcher, destroy them and call into libadns. What follows is pseudo-code only of course. This requires you to either use a low priority for the check watcher or use \f(CW\*(C`ev_clear_pending\*(C'\fR explicitly, as the callbacks for the IO/timeout watchers might not have been called yet. .PP .Vb 2 \& static ev_io iow [nfd]; \& static ev_timer tw; .Ve .PP .Vb 4 \& static void \& io_cb (ev_loop *loop, ev_io *w, int revents) \& { \& } .Ve .PP .Vb 8 \& // create io watchers for each fd and a timer before blocking \& static void \& adns_prepare_cb (ev_loop *loop, ev_prepare *w, int revents) \& { \& int timeout = 3600000; \& struct pollfd fds [nfd]; \& // actual code will need to loop here and realloc etc. \& adns_beforepoll (ads, fds, &nfd, &timeout, timeval_from (ev_time ())); .Ve .PP .Vb 3 \& /* the callback is illegal, but won't be called as we stop during check */ \& ev_timer_init (&tw, 0, timeout * 1e-3); \& ev_timer_start (loop, &tw); .Ve .PP .Vb 6 \& // create one ev_io per pollfd \& for (int i = 0; i < nfd; ++i) \& { \& ev_io_init (iow + i, io_cb, fds [i].fd, \& ((fds [i].events & POLLIN ? EV_READ : 0) \& | (fds [i].events & POLLOUT ? EV_WRITE : 0))); .Ve .PP .Vb 4 \& fds [i].revents = 0; \& ev_io_start (loop, iow + i); \& } \& } .Ve .PP .Vb 5 \& // stop all watchers after blocking \& static void \& adns_check_cb (ev_loop *loop, ev_check *w, int revents) \& { \& ev_timer_stop (loop, &tw); .Ve .PP .Vb 8 \& for (int i = 0; i < nfd; ++i) \& { \& // set the relevant poll flags \& // could also call adns_processreadable etc. here \& struct pollfd *fd = fds + i; \& int revents = ev_clear_pending (iow + i); \& if (revents & EV_READ ) fd->revents |= fd->events & POLLIN; \& if (revents & EV_WRITE) fd->revents |= fd->events & POLLOUT; .Ve .PP .Vb 3 \& // now stop the watcher \& ev_io_stop (loop, iow + i); \& } .Ve .PP .Vb 2 \& adns_afterpoll (adns, fds, nfd, timeval_from (ev_now (loop)); \& } .Ve .PP Method 2: This would be just like method 1, but you run \f(CW\*(C`adns_afterpoll\*(C'\fR in the prepare watcher and would dispose of the check watcher. .PP Method 3: If the module to be embedded supports explicit event notification (adns does), you can also make use of the actual watcher callbacks, and only destroy/create the watchers in the prepare watcher. .PP .Vb 5 \& static void \& timer_cb (EV_P_ ev_timer *w, int revents) \& { \& adns_state ads = (adns_state)w->data; \& update_now (EV_A); .Ve .PP .Vb 2 \& adns_processtimeouts (ads, &tv_now); \& } .Ve .PP .Vb 5 \& static void \& io_cb (EV_P_ ev_io *w, int revents) \& { \& adns_state ads = (adns_state)w->data; \& update_now (EV_A); .Ve .PP .Vb 3 \& if (revents & EV_READ ) adns_processreadable (ads, w->fd, &tv_now); \& if (revents & EV_WRITE) adns_processwriteable (ads, w->fd, &tv_now); \& } .Ve .PP .Vb 1 \& // do not ever call adns_afterpoll .Ve .PP Method 4: Do not use a prepare or check watcher because the module you want to embed is too inflexible to support it. Instead, youc na override their poll function. The drawback with this solution is that the main loop is now no longer controllable by \s-1EV\s0. The \f(CW\*(C`Glib::EV\*(C'\fR module does this. .PP .Vb 4 \& static gint \& event_poll_func (GPollFD *fds, guint nfds, gint timeout) \& { \& int got_events = 0; .Ve .PP .Vb 2 \& for (n = 0; n < nfds; ++n) \& // create/start io watcher that sets the relevant bits in fds[n] and increment got_events .Ve .PP .Vb 2 \& if (timeout >= 0) \& // create/start timer .Ve .PP .Vb 2 \& // poll \& ev_loop (EV_A_ 0); .Ve .PP .Vb 3 \& // stop timer again \& if (timeout >= 0) \& ev_timer_stop (EV_A_ &to); .Ve .PP .Vb 3 \& // stop io watchers again - their callbacks should have set \& for (n = 0; n < nfds; ++n) \& ev_io_stop (EV_A_ iow [n]); .Ve .PP .Vb 2 \& return got_events; \& } .Ve .ie n .Sh """ev_embed"" \- when one backend isn't enough..." .el .Sh "\f(CWev_embed\fP \- when one backend isn't enough..." .IX Subsection "ev_embed - when one backend isn't enough..." This is a rather advanced watcher type that lets you embed one event loop into another (currently only \f(CW\*(C`ev_io\*(C'\fR events are supported in the embedded loop, other types of watchers might be handled in a delayed or incorrect fashion and must not be used). .PP There are primarily two reasons you would want that: work around bugs and prioritise I/O. .PP As an example for a bug workaround, the kqueue backend might only support sockets on some platform, so it is unusable as generic backend, but you still want to make use of it because you have many sockets and it scales so nicely. In this case, you would create a kqueue-based loop and embed it into your default loop (which might use e.g. poll). Overall operation will be a bit slower because first libev has to poll and then call kevent, but at least you can use both at what they are best. .PP As for prioritising I/O: rarely you have the case where some fds have to be watched and handled very quickly (with low latency), and even priorities and idle watchers might have too much overhead. In this case you would put all the high priority stuff in one loop and all the rest in a second one, and embed the second one in the first. .PP As long as the watcher is active, the callback will be invoked every time there might be events pending in the embedded loop. The callback must then call \f(CW\*(C`ev_embed_sweep (mainloop, watcher)\*(C'\fR to make a single sweep and invoke their callbacks (you could also start an idle watcher to give the embedded loop strictly lower priority for example). You can also set the callback to \f(CW0\fR, in which case the embed watcher will automatically execute the embedded loop sweep. .PP As long as the watcher is started it will automatically handle events. The callback will be invoked whenever some events have been handled. You can set the callback to \f(CW0\fR to avoid having to specify one if you are not interested in that. .PP Also, there have not currently been made special provisions for forking: when you fork, you not only have to call \f(CW\*(C`ev_loop_fork\*(C'\fR on both loops, but you will also have to stop and restart any \f(CW\*(C`ev_embed\*(C'\fR watchers yourself. .PP Unfortunately, not all backends are embeddable, only the ones returned by \&\f(CW\*(C`ev_embeddable_backends\*(C'\fR are, which, unfortunately, does not include any portable one. .PP So when you want to use this feature you will always have to be prepared that you cannot get an embeddable loop. The recommended way to get around this is to have a separate variables for your embeddable loop, try to create it, and if that fails, use the normal loop for everything: .PP .Vb 3 \& struct ev_loop *loop_hi = ev_default_init (0); \& struct ev_loop *loop_lo = 0; \& struct ev_embed embed; .Ve .PP .Vb 5 \& // see if there is a chance of getting one that works \& // (remember that a flags value of 0 means autodetection) \& loop_lo = ev_embeddable_backends () & ev_recommended_backends () \& ? ev_loop_new (ev_embeddable_backends () & ev_recommended_backends ()) \& : 0; .Ve .PP .Vb 8 \& // if we got one, then embed it, otherwise default to loop_hi \& if (loop_lo) \& { \& ev_embed_init (&embed, 0, loop_lo); \& ev_embed_start (loop_hi, &embed); \& } \& else \& loop_lo = loop_hi; .Ve .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_embed_init (ev_embed *, callback, struct ev_loop *embedded_loop)" 4 .IX Item "ev_embed_init (ev_embed *, callback, struct ev_loop *embedded_loop)" .PD 0 .IP "ev_embed_set (ev_embed *, callback, struct ev_loop *embedded_loop)" 4 .IX Item "ev_embed_set (ev_embed *, callback, struct ev_loop *embedded_loop)" .PD Configures the watcher to embed the given loop, which must be embeddable. If the callback is \f(CW0\fR, then \f(CW\*(C`ev_embed_sweep\*(C'\fR will be invoked automatically, otherwise it is the responsibility of the callback to invoke it (it will continue to be called until the sweep has been done, if you do not want thta, you need to temporarily stop the embed watcher). .IP "ev_embed_sweep (loop, ev_embed *)" 4 .IX Item "ev_embed_sweep (loop, ev_embed *)" Make a single, non-blocking sweep over the embedded loop. This works similarly to \f(CW\*(C`ev_loop (embedded_loop, EVLOOP_NONBLOCK)\*(C'\fR, but in the most apropriate way for embedded loops. .IP "struct ev_loop *other [read\-only]" 4 .IX Item "struct ev_loop *other [read-only]" The embedded event loop. .ie n .Sh """ev_fork"" \- the audacity to resume the event loop after a fork" .el .Sh "\f(CWev_fork\fP \- the audacity to resume the event loop after a fork" .IX Subsection "ev_fork - the audacity to resume the event loop after a fork" Fork watchers are called when a \f(CW\*(C`fork ()\*(C'\fR was detected (usually because whoever is a good citizen cared to tell libev about it by calling \&\f(CW\*(C`ev_default_fork\*(C'\fR or \f(CW\*(C`ev_loop_fork\*(C'\fR). The invocation is done before the event loop blocks next and before \f(CW\*(C`ev_check\*(C'\fR watchers are being called, and only in the child after the fork. If whoever good citizen calling \&\f(CW\*(C`ev_default_fork\*(C'\fR cheats and calls it in the wrong process, the fork handlers will be invoked, too, of course. .PP \fIWatcher-Specific Functions and Data Members\fR .IX Subsection "Watcher-Specific Functions and Data Members" .IP "ev_fork_init (ev_signal *, callback)" 4 .IX Item "ev_fork_init (ev_signal *, callback)" Initialises and configures the fork watcher \- it has no parameters of any kind. There is a \f(CW\*(C`ev_fork_set\*(C'\fR macro, but using it is utterly pointless, believe me. .SH "OTHER FUNCTIONS" .IX Header "OTHER FUNCTIONS" There are some other functions of possible interest. Described. Here. Now. .IP "ev_once (loop, int fd, int events, ev_tstamp timeout, callback)" 4 .IX Item "ev_once (loop, int fd, int events, ev_tstamp timeout, callback)" This function combines a simple timer and an I/O watcher, calls your callback on whichever event happens first and automatically stop both watchers. This is useful if you want to wait for a single event on an fd or timeout without having to allocate/configure/start/stop/free one or more watchers yourself. .Sp If \f(CW\*(C`fd\*(C'\fR is less than 0, then no I/O watcher will be started and events is being ignored. Otherwise, an \f(CW\*(C`ev_io\*(C'\fR watcher for the given \f(CW\*(C`fd\*(C'\fR and \&\f(CW\*(C`events\*(C'\fR set will be craeted and started. .Sp If \f(CW\*(C`timeout\*(C'\fR is less than 0, then no timeout watcher will be started. Otherwise an \f(CW\*(C`ev_timer\*(C'\fR watcher with after = \f(CW\*(C`timeout\*(C'\fR (and repeat = 0) will be started. While \f(CW0\fR is a valid timeout, it is of dubious value. .Sp The callback has the type \f(CW\*(C`void (*cb)(int revents, void *arg)\*(C'\fR and gets passed an \f(CW\*(C`revents\*(C'\fR set like normal event callbacks (a combination of \&\f(CW\*(C`EV_ERROR\*(C'\fR, \f(CW\*(C`EV_READ\*(C'\fR, \f(CW\*(C`EV_WRITE\*(C'\fR or \f(CW\*(C`EV_TIMEOUT\*(C'\fR) and the \f(CW\*(C`arg\*(C'\fR value passed to \f(CW\*(C`ev_once\*(C'\fR: .Sp .Vb 7 \& static void stdin_ready (int revents, void *arg) \& { \& if (revents & EV_TIMEOUT) \& /* doh, nothing entered */; \& else if (revents & EV_READ) \& /* stdin might have data for us, joy! */; \& } .Ve .Sp .Vb 1 \& ev_once (STDIN_FILENO, EV_READ, 10., stdin_ready, 0); .Ve .IP "ev_feed_event (ev_loop *, watcher *, int revents)" 4 .IX Item "ev_feed_event (ev_loop *, watcher *, int revents)" Feeds the given event set into the event loop, as if the specified event had happened for the specified watcher (which must be a pointer to an initialised but not necessarily started event watcher). .IP "ev_feed_fd_event (ev_loop *, int fd, int revents)" 4 .IX Item "ev_feed_fd_event (ev_loop *, int fd, int revents)" Feed an event on the given fd, as if a file descriptor backend detected the given events it. .IP "ev_feed_signal_event (ev_loop *loop, int signum)" 4 .IX Item "ev_feed_signal_event (ev_loop *loop, int signum)" Feed an event as if the given signal occured (\f(CW\*(C`loop\*(C'\fR must be the default loop!). .SH "LIBEVENT EMULATION" .IX Header "LIBEVENT EMULATION" Libev offers a compatibility emulation layer for libevent. It cannot emulate the internals of libevent, so here are some usage hints: .IP "* Use it by including <event.h>, as usual." 4 .IX Item "Use it by including <event.h>, as usual." .PD 0 .IP "* The following members are fully supported: ev_base, ev_callback, ev_arg, ev_fd, ev_res, ev_events." 4 .IX Item "The following members are fully supported: ev_base, ev_callback, ev_arg, ev_fd, ev_res, ev_events." .IP "* Avoid using ev_flags and the EVLIST_*\-macros, while it is maintained by libev, it does not work exactly the same way as in libevent (consider it a private \s-1API\s0)." 4 .IX Item "Avoid using ev_flags and the EVLIST_*-macros, while it is maintained by libev, it does not work exactly the same way as in libevent (consider it a private API)." .IP "* Priorities are not currently supported. Initialising priorities will fail and all watchers will have the same priority, even though there is an ev_pri field." 4 .IX Item "Priorities are not currently supported. Initialising priorities will fail and all watchers will have the same priority, even though there is an ev_pri field." .IP "* Other members are not supported." 4 .IX Item "Other members are not supported." .IP "* The libev emulation is \fInot\fR \s-1ABI\s0 compatible to libevent, you need to use the libev header file and library." 4 .IX Item "The libev emulation is not ABI compatible to libevent, you need to use the libev header file and library." .PD .SH "\*(C+ SUPPORT" .IX Header " SUPPORT" Libev comes with some simplistic wrapper classes for \*(C+ that mainly allow you to use some convinience methods to start/stop watchers and also change the callback model to a model using method callbacks on objects. .PP To use it, .PP .Vb 1 \& #include <ev++.h> .Ve .PP This automatically includes \fIev.h\fR and puts all of its definitions (many of them macros) into the global namespace. All \*(C+ specific things are put into the \f(CW\*(C`ev\*(C'\fR namespace. It should support all the same embedding options as \fIev.h\fR, most notably \f(CW\*(C`EV_MULTIPLICITY\*(C'\fR. .PP Care has been taken to keep the overhead low. The only data member the \*(C+ classes add (compared to plain C\-style watchers) is the event loop pointer that the watcher is associated with (or no additional members at all if you disable \f(CW\*(C`EV_MULTIPLICITY\*(C'\fR when embedding libev). .PP Currently, functions, and static and non-static member functions can be used as callbacks. Other types should be easy to add as long as they only need one additional pointer for context. If you need support for other types of functors please contact the author (preferably after implementing it). .PP Here is a list of things available in the \f(CW\*(C`ev\*(C'\fR namespace: .ie n .IP """ev::READ""\fR, \f(CW""ev::WRITE"" etc." 4 .el .IP "\f(CWev::READ\fR, \f(CWev::WRITE\fR etc." 4 .IX Item "ev::READ, ev::WRITE etc." These are just enum values with the same values as the \f(CW\*(C`EV_READ\*(C'\fR etc. macros from \fIev.h\fR. .ie n .IP """ev::tstamp""\fR, \f(CW""ev::now""" 4 .el .IP "\f(CWev::tstamp\fR, \f(CWev::now\fR" 4 .IX Item "ev::tstamp, ev::now" Aliases to the same types/functions as with the \f(CW\*(C`ev_\*(C'\fR prefix. .ie n .IP """ev::io""\fR, \f(CW""ev::timer""\fR, \f(CW""ev::periodic""\fR, \f(CW""ev::idle""\fR, \f(CW""ev::sig"" etc." 4 .el .IP "\f(CWev::io\fR, \f(CWev::timer\fR, \f(CWev::periodic\fR, \f(CWev::idle\fR, \f(CWev::sig\fR etc." 4 .IX Item "ev::io, ev::timer, ev::periodic, ev::idle, ev::sig etc." For each \f(CW\*(C`ev_TYPE\*(C'\fR watcher in \fIev.h\fR there is a corresponding class of the same name in the \f(CW\*(C`ev\*(C'\fR namespace, with the exception of \f(CW\*(C`ev_signal\*(C'\fR which is called \f(CW\*(C`ev::sig\*(C'\fR to avoid clashes with the \f(CW\*(C`signal\*(C'\fR macro defines by many implementations. .Sp All of those classes have these methods: .RS 4 .IP "ev::TYPE::TYPE ()" 4 .IX Item "ev::TYPE::TYPE ()" .PD 0 .IP "ev::TYPE::TYPE (struct ev_loop *)" 4 .IX Item "ev::TYPE::TYPE (struct ev_loop *)" .IP "ev::TYPE::~TYPE" 4 .IX Item "ev::TYPE::~TYPE" .PD The constructor (optionally) takes an event loop to associate the watcher with. If it is omitted, it will use \f(CW\*(C`EV_DEFAULT\*(C'\fR. .Sp The constructor calls \f(CW\*(C`ev_init\*(C'\fR for you, which means you have to call the \&\f(CW\*(C`set\*(C'\fR method before starting it. .Sp It will not set a callback, however: You have to call the templated \f(CW\*(C`set\*(C'\fR method to set a callback before you can start the watcher. .Sp (The reason why you have to use a method is a limitation in \*(C+ which does not allow explicit template arguments for constructors). .Sp The destructor automatically stops the watcher if it is active. .IP "w\->set<class, &class::method> (object *)" 4 .IX Item "w->set<class, &class::method> (object *)" This method sets the callback method to call. The method has to have a signature of \f(CW\*(C`void (*)(ev_TYPE &, int)\*(C'\fR, it receives the watcher as first argument and the \f(CW\*(C`revents\*(C'\fR as second. The object must be given as parameter and is stored in the \f(CW\*(C`data\*(C'\fR member of the watcher. .Sp This method synthesizes efficient thunking code to call your method from the C callback that libev requires. If your compiler can inline your callback (i.e. it is visible to it at the place of the \f(CW\*(C`set\*(C'\fR call and your compiler is good :), then the method will be fully inlined into the thunking function, making it as fast as a direct C callback. .Sp Example: simple class declaration and watcher initialisation .Sp .Vb 4 \& struct myclass \& { \& void io_cb (ev::io &w, int revents) { } \& } .Ve .Sp .Vb 3 \& myclass obj; \& ev::io iow; \& iow.set <myclass, &myclass::io_cb> (&obj); .Ve .IP "w\->set<function> (void *data = 0)" 4 .IX Item "w->set<function> (void *data = 0)" Also sets a callback, but uses a static method or plain function as callback. The optional \f(CW\*(C`data\*(C'\fR argument will be stored in the watcher's \&\f(CW\*(C`data\*(C'\fR member and is free for you to use. .Sp The prototype of the \f(CW\*(C`function\*(C'\fR must be \f(CW\*(C`void (*)(ev::TYPE &w, int)\*(C'\fR. .Sp See the method\-\f(CW\*(C`set\*(C'\fR above for more details. .Sp Example: .Sp .Vb 2 \& static void io_cb (ev::io &w, int revents) { } \& iow.set <io_cb> (); .Ve .IP "w\->set (struct ev_loop *)" 4 .IX Item "w->set (struct ev_loop *)" Associates a different \f(CW\*(C`struct ev_loop\*(C'\fR with this watcher. You can only do this when the watcher is inactive (and not pending either). .IP "w\->set ([args])" 4 .IX Item "w->set ([args])" Basically the same as \f(CW\*(C`ev_TYPE_set\*(C'\fR, with the same args. Must be called at least once. Unlike the C counterpart, an active watcher gets automatically stopped and restarted when reconfiguring it with this method. .IP "w\->start ()" 4 .IX Item "w->start ()" Starts the watcher. Note that there is no \f(CW\*(C`loop\*(C'\fR argument, as the constructor already stores the event loop. .IP "w\->stop ()" 4 .IX Item "w->stop ()" Stops the watcher if it is active. Again, no \f(CW\*(C`loop\*(C'\fR argument. .ie n .IP "w\->again () (""ev::timer""\fR, \f(CW""ev::periodic"" only)" 4 .el .IP "w\->again () (\f(CWev::timer\fR, \f(CWev::periodic\fR only)" 4 .IX Item "w->again () (ev::timer, ev::periodic only)" For \f(CW\*(C`ev::timer\*(C'\fR and \f(CW\*(C`ev::periodic\*(C'\fR, this invokes the corresponding \&\f(CW\*(C`ev_TYPE_again\*(C'\fR function. .ie n .IP "w\->sweep () (""ev::embed"" only)" 4 .el .IP "w\->sweep () (\f(CWev::embed\fR only)" 4 .IX Item "w->sweep () (ev::embed only)" Invokes \f(CW\*(C`ev_embed_sweep\*(C'\fR. .ie n .IP "w\->update () (""ev::stat"" only)" 4 .el .IP "w\->update () (\f(CWev::stat\fR only)" 4 .IX Item "w->update () (ev::stat only)" Invokes \f(CW\*(C`ev_stat_stat\*(C'\fR. .RE .RS 4 .RE .PP Example: Define a class with an \s-1IO\s0 and idle watcher, start one of them in the constructor. .PP .Vb 4 \& class myclass \& { \& ev_io io; void io_cb (ev::io &w, int revents); \& ev_idle idle void idle_cb (ev::idle &w, int revents); .Ve .PP .Vb 2 \& myclass (); \& } .Ve .PP .Vb 4 \& myclass::myclass (int fd) \& { \& io .set <myclass, &myclass::io_cb > (this); \& idle.set <myclass, &myclass::idle_cb> (this); .Ve .PP .Vb 2 \& io.start (fd, ev::READ); \& } .Ve .SH "MACRO MAGIC" .IX Header "MACRO MAGIC" Libev can be compiled with a variety of options, the most fundamantal of which is \f(CW\*(C`EV_MULTIPLICITY\*(C'\fR. This option determines whether (most) functions and callbacks have an initial \f(CW\*(C`struct ev_loop *\*(C'\fR argument. .PP To make it easier to write programs that cope with either variant, the following macros are defined: .ie n .IP """EV_A""\fR, \f(CW""EV_A_""" 4 .el .IP "\f(CWEV_A\fR, \f(CWEV_A_\fR" 4 .IX Item "EV_A, EV_A_" This provides the loop \fIargument\fR for functions, if one is required (\*(L"ev loop argument\*(R"). The \f(CW\*(C`EV_A\*(C'\fR form is used when this is the sole argument, \&\f(CW\*(C`EV_A_\*(C'\fR is used when other arguments are following. Example: .Sp .Vb 3 \& ev_unref (EV_A); \& ev_timer_add (EV_A_ watcher); \& ev_loop (EV_A_ 0); .Ve .Sp It assumes the variable \f(CW\*(C`loop\*(C'\fR of type \f(CW\*(C`struct ev_loop *\*(C'\fR is in scope, which is often provided by the following macro. .ie n .IP """EV_P""\fR, \f(CW""EV_P_""" 4 .el .IP "\f(CWEV_P\fR, \f(CWEV_P_\fR" 4 .IX Item "EV_P, EV_P_" This provides the loop \fIparameter\fR for functions, if one is required (\*(L"ev loop parameter\*(R"). The \f(CW\*(C`EV_P\*(C'\fR form is used when this is the sole parameter, \&\f(CW\*(C`EV_P_\*(C'\fR is used when other parameters are following. Example: .Sp .Vb 2 \& // this is how ev_unref is being declared \& static void ev_unref (EV_P); .Ve .Sp .Vb 2 \& // this is how you can declare your typical callback \& static void cb (EV_P_ ev_timer *w, int revents) .Ve .Sp It declares a parameter \f(CW\*(C`loop\*(C'\fR of type \f(CW\*(C`struct ev_loop *\*(C'\fR, quite suitable for use with \f(CW\*(C`EV_A\*(C'\fR. .ie n .IP """EV_DEFAULT""\fR, \f(CW""EV_DEFAULT_""" 4 .el .IP "\f(CWEV_DEFAULT\fR, \f(CWEV_DEFAULT_\fR" 4 .IX Item "EV_DEFAULT, EV_DEFAULT_" Similar to the other two macros, this gives you the value of the default loop, if multiple loops are supported (\*(L"ev loop default\*(R"). .PP Example: Declare and initialise a check watcher, utilising the above macros so it will work regardless of whether multiple loops are supported or not. .PP .Vb 5 \& static void \& check_cb (EV_P_ ev_timer *w, int revents) \& { \& ev_check_stop (EV_A_ w); \& } .Ve .PP .Vb 4 \& ev_check check; \& ev_check_init (&check, check_cb); \& ev_check_start (EV_DEFAULT_ &check); \& ev_loop (EV_DEFAULT_ 0); .Ve .SH "EMBEDDING" .IX Header "EMBEDDING" Libev can (and often is) directly embedded into host applications. Examples of applications that embed it include the Deliantra Game Server, the \s-1EV\s0 perl module, the \s-1GNU\s0 Virtual Private Ethernet (gvpe) and rxvt\-unicode. .PP The goal is to enable you to just copy the necessary files into your source directory without having to change even a single line in them, so you can easily upgrade by simply copying (or having a checked-out copy of libev somewhere in your source tree). .Sh "\s-1FILESETS\s0" .IX Subsection "FILESETS" Depending on what features you need you need to include one or more sets of files in your app. .PP \fI\s-1CORE\s0 \s-1EVENT\s0 \s-1LOOP\s0\fR .IX Subsection "CORE EVENT LOOP" .PP To include only the libev core (all the \f(CW\*(C`ev_*\*(C'\fR functions), with manual configuration (no autoconf): .PP .Vb 2 \& #define EV_STANDALONE 1 \& #include "ev.c" .Ve .PP This will automatically include \fIev.h\fR, too, and should be done in a single C source file only to provide the function implementations. To use it, do the same for \fIev.h\fR in all files wishing to use this \s-1API\s0 (best done by writing a wrapper around \fIev.h\fR that you can include instead and where you can put other configuration options): .PP .Vb 2 \& #define EV_STANDALONE 1 \& #include "ev.h" .Ve .PP Both header files and implementation files can be compiled with a \*(C+ compiler (at least, thats a stated goal, and breakage will be treated as a bug). .PP You need the following files in your source tree, or in a directory in your include path (e.g. in libev/ when using \-Ilibev): .PP .Vb 4 \& ev.h \& ev.c \& ev_vars.h \& ev_wrap.h .Ve .PP .Vb 1 \& ev_win32.c required on win32 platforms only .Ve .PP .Vb 5 \& ev_select.c only when select backend is enabled (which is enabled by default) \& ev_poll.c only when poll backend is enabled (disabled by default) \& ev_epoll.c only when the epoll backend is enabled (disabled by default) \& ev_kqueue.c only when the kqueue backend is enabled (disabled by default) \& ev_port.c only when the solaris port backend is enabled (disabled by default) .Ve .PP \&\fIev.c\fR includes the backend files directly when enabled, so you only need to compile this single file. .PP \fI\s-1LIBEVENT\s0 \s-1COMPATIBILITY\s0 \s-1API\s0\fR .IX Subsection "LIBEVENT COMPATIBILITY API" .PP To include the libevent compatibility \s-1API\s0, also include: .PP .Vb 1 \& #include "event.c" .Ve .PP in the file including \fIev.c\fR, and: .PP .Vb 1 \& #include "event.h" .Ve .PP in the files that want to use the libevent \s-1API\s0. This also includes \fIev.h\fR. .PP You need the following additional files for this: .PP .Vb 2 \& event.h \& event.c .Ve .PP \fI\s-1AUTOCONF\s0 \s-1SUPPORT\s0\fR .IX Subsection "AUTOCONF SUPPORT" .PP Instead of using \f(CW\*(C`EV_STANDALONE=1\*(C'\fR and providing your config in whatever way you want, you can also \f(CW\*(C`m4_include([libev.m4])\*(C'\fR in your \&\fIconfigure.ac\fR and leave \f(CW\*(C`EV_STANDALONE\*(C'\fR undefined. \fIev.c\fR will then include \fIconfig.h\fR and configure itself accordingly. .PP For this of course you need the m4 file: .PP .Vb 1 \& libev.m4 .Ve .Sh "\s-1PREPROCESSOR\s0 \s-1SYMBOLS/MACROS\s0" .IX Subsection "PREPROCESSOR SYMBOLS/MACROS" Libev can be configured via a variety of preprocessor symbols you have to define before including any of its files. The default is not to build for multiplicity and only include the select backend. .IP "\s-1EV_STANDALONE\s0" 4 .IX Item "EV_STANDALONE" Must always be \f(CW1\fR if you do not use autoconf configuration, which keeps libev from including \fIconfig.h\fR, and it also defines dummy implementations for some libevent functions (such as logging, which is not supported). It will also not define any of the structs usually found in \&\fIevent.h\fR that are not directly supported by the libev core alone. .IP "\s-1EV_USE_MONOTONIC\s0" 4 .IX Item "EV_USE_MONOTONIC" If defined to be \f(CW1\fR, libev will try to detect the availability of the monotonic clock option at both compiletime and runtime. Otherwise no use of the monotonic clock option will be attempted. If you enable this, you usually have to link against librt or something similar. Enabling it when the functionality isn't available is safe, though, although you have to make sure you link against any libraries where the \f(CW\*(C`clock_gettime\*(C'\fR function is hiding in (often \fI\-lrt\fR). .IP "\s-1EV_USE_REALTIME\s0" 4 .IX Item "EV_USE_REALTIME" If defined to be \f(CW1\fR, libev will try to detect the availability of the realtime clock option at compiletime (and assume its availability at runtime if successful). Otherwise no use of the realtime clock option will be attempted. This effectively replaces \f(CW\*(C`gettimeofday\*(C'\fR by \f(CW\*(C`clock_get (CLOCK_REALTIME, ...)\*(C'\fR and will not normally affect correctness. See the note about libraries in the description of \f(CW\*(C`EV_USE_MONOTONIC\*(C'\fR, though. .IP "\s-1EV_USE_NANOSLEEP\s0" 4 .IX Item "EV_USE_NANOSLEEP" If defined to be \f(CW1\fR, libev will assume that \f(CW\*(C`nanosleep ()\*(C'\fR is available and will use it for delays. Otherwise it will use \f(CW\*(C`select ()\*(C'\fR. .IP "\s-1EV_USE_SELECT\s0" 4 .IX Item "EV_USE_SELECT" If undefined or defined to be \f(CW1\fR, libev will compile in support for the \&\f(CW\*(C`select\*(C'\fR(2) backend. No attempt at autodetection will be done: if no other method takes over, select will be it. Otherwise the select backend will not be compiled in. .IP "\s-1EV_SELECT_USE_FD_SET\s0" 4 .IX Item "EV_SELECT_USE_FD_SET" If defined to \f(CW1\fR, then the select backend will use the system \f(CW\*(C`fd_set\*(C'\fR structure. This is useful if libev doesn't compile due to a missing \&\f(CW\*(C`NFDBITS\*(C'\fR or \f(CW\*(C`fd_mask\*(C'\fR definition or it misguesses the bitset layout on exotic systems. This usually limits the range of file descriptors to some low limit such as 1024 or might have other limitations (winsocket only allows 64 sockets). The \f(CW\*(C`FD_SETSIZE\*(C'\fR macro, set before compilation, might influence the size of the \f(CW\*(C`fd_set\*(C'\fR used. .IP "\s-1EV_SELECT_IS_WINSOCKET\s0" 4 .IX Item "EV_SELECT_IS_WINSOCKET" When defined to \f(CW1\fR, the select backend will assume that select/socket/connect etc. don't understand file descriptors but wants osf handles on win32 (this is the case when the select to be used is the winsock select). This means that it will call \&\f(CW\*(C`_get_osfhandle\*(C'\fR on the fd to convert it to an \s-1OS\s0 handle. Otherwise, it is assumed that all these functions actually work on fds, even on win32. Should not be defined on non\-win32 platforms. .IP "\s-1EV_USE_POLL\s0" 4 .IX Item "EV_USE_POLL" If defined to be \f(CW1\fR, libev will compile in support for the \f(CW\*(C`poll\*(C'\fR(2) backend. Otherwise it will be enabled on non\-win32 platforms. It takes precedence over select. .IP "\s-1EV_USE_EPOLL\s0" 4 .IX Item "EV_USE_EPOLL" If defined to be \f(CW1\fR, libev will compile in support for the Linux \&\f(CW\*(C`epoll\*(C'\fR(7) backend. Its availability will be detected at runtime, otherwise another method will be used as fallback. This is the preferred backend for GNU/Linux systems. .IP "\s-1EV_USE_KQUEUE\s0" 4 .IX Item "EV_USE_KQUEUE" If defined to be \f(CW1\fR, libev will compile in support for the \s-1BSD\s0 style \&\f(CW\*(C`kqueue\*(C'\fR(2) backend. Its actual availability will be detected at runtime, otherwise another method will be used as fallback. This is the preferred backend for \s-1BSD\s0 and BSD-like systems, although on most BSDs kqueue only supports some types of fds correctly (the only platform we found that supports ptys for example was NetBSD), so kqueue might be compiled in, but not be used unless explicitly requested. The best way to use it is to find out whether kqueue supports your type of fd properly and use an embedded kqueue loop. .IP "\s-1EV_USE_PORT\s0" 4 .IX Item "EV_USE_PORT" If defined to be \f(CW1\fR, libev will compile in support for the Solaris 10 port style backend. Its availability will be detected at runtime, otherwise another method will be used as fallback. This is the preferred backend for Solaris 10 systems. .IP "\s-1EV_USE_DEVPOLL\s0" 4 .IX Item "EV_USE_DEVPOLL" reserved for future expansion, works like the \s-1USE\s0 symbols above. .IP "\s-1EV_USE_INOTIFY\s0" 4 .IX Item "EV_USE_INOTIFY" If defined to be \f(CW1\fR, libev will compile in support for the Linux inotify interface to speed up \f(CW\*(C`ev_stat\*(C'\fR watchers. Its actual availability will be detected at runtime. .IP "\s-1EV_H\s0" 4 .IX Item "EV_H" The name of the \fIev.h\fR header file used to include it. The default if undefined is \f(CW"ev.h"\fR in \fIevent.h\fR and \fIev.c\fR. This can be used to virtually rename the \fIev.h\fR header file in case of conflicts. .IP "\s-1EV_CONFIG_H\s0" 4 .IX Item "EV_CONFIG_H" If \f(CW\*(C`EV_STANDALONE\*(C'\fR isn't \f(CW1\fR, this variable can be used to override \&\fIev.c\fR's idea of where to find the \fIconfig.h\fR file, similarly to \&\f(CW\*(C`EV_H\*(C'\fR, above. .IP "\s-1EV_EVENT_H\s0" 4 .IX Item "EV_EVENT_H" Similarly to \f(CW\*(C`EV_H\*(C'\fR, this macro can be used to override \fIevent.c\fR's idea of how the \fIevent.h\fR header can be found, the dfeault is \f(CW"event.h"\fR. .IP "\s-1EV_PROTOTYPES\s0" 4 .IX Item "EV_PROTOTYPES" If defined to be \f(CW0\fR, then \fIev.h\fR will not define any function prototypes, but still define all the structs and other symbols. This is occasionally useful if you want to provide your own wrapper functions around libev functions. .IP "\s-1EV_MULTIPLICITY\s0" 4 .IX Item "EV_MULTIPLICITY" If undefined or defined to \f(CW1\fR, then all event-loop-specific functions will have the \f(CW\*(C`struct ev_loop *\*(C'\fR as first argument, and you can create additional independent event loops. Otherwise there will be no support for multiple event loops and there is no first event loop pointer argument. Instead, all functions act on the single default loop. .IP "\s-1EV_MINPRI\s0" 4 .IX Item "EV_MINPRI" .PD 0 .IP "\s-1EV_MAXPRI\s0" 4 .IX Item "EV_MAXPRI" .PD The range of allowed priorities. \f(CW\*(C`EV_MINPRI\*(C'\fR must be smaller or equal to \&\f(CW\*(C`EV_MAXPRI\*(C'\fR, but otherwise there are no non-obvious limitations. You can provide for more priorities by overriding those symbols (usually defined to be \f(CW\*(C`\-2\*(C'\fR and \f(CW2\fR, respectively). .Sp When doing priority-based operations, libev usually has to linearly search all the priorities, so having many of them (hundreds) uses a lot of space and time, so using the defaults of five priorities (\-2 .. +2) is usually fine. .Sp If your embedding app does not need any priorities, defining these both to \&\f(CW0\fR will save some memory and cpu. .IP "\s-1EV_PERIODIC_ENABLE\s0" 4 .IX Item "EV_PERIODIC_ENABLE" If undefined or defined to be \f(CW1\fR, then periodic timers are supported. If defined to be \f(CW0\fR, then they are not. Disabling them saves a few kB of code. .IP "\s-1EV_IDLE_ENABLE\s0" 4 .IX Item "EV_IDLE_ENABLE" If undefined or defined to be \f(CW1\fR, then idle watchers are supported. If defined to be \f(CW0\fR, then they are not. Disabling them saves a few kB of code. .IP "\s-1EV_EMBED_ENABLE\s0" 4 .IX Item "EV_EMBED_ENABLE" If undefined or defined to be \f(CW1\fR, then embed watchers are supported. If defined to be \f(CW0\fR, then they are not. .IP "\s-1EV_STAT_ENABLE\s0" 4 .IX Item "EV_STAT_ENABLE" If undefined or defined to be \f(CW1\fR, then stat watchers are supported. If defined to be \f(CW0\fR, then they are not. .IP "\s-1EV_FORK_ENABLE\s0" 4 .IX Item "EV_FORK_ENABLE" If undefined or defined to be \f(CW1\fR, then fork watchers are supported. If defined to be \f(CW0\fR, then they are not. .IP "\s-1EV_MINIMAL\s0" 4 .IX Item "EV_MINIMAL" If you need to shave off some kilobytes of code at the expense of some speed, define this symbol to \f(CW1\fR. Currently only used for gcc to override some inlining decisions, saves roughly 30% codesize of amd64. .IP "\s-1EV_PID_HASHSIZE\s0" 4 .IX Item "EV_PID_HASHSIZE" \&\f(CW\*(C`ev_child\*(C'\fR watchers use a small hash table to distribute workload by pid. The default size is \f(CW16\fR (or \f(CW1\fR with \f(CW\*(C`EV_MINIMAL\*(C'\fR), usually more than enough. If you need to manage thousands of children you might want to increase this value (\fImust\fR be a power of two). .IP "\s-1EV_INOTIFY_HASHSIZE\s0" 4 .IX Item "EV_INOTIFY_HASHSIZE" \&\f(CW\*(C`ev_stat\*(C'\fR watchers use a small hash table to distribute workload by inotify watch id. The default size is \f(CW16\fR (or \f(CW1\fR with \f(CW\*(C`EV_MINIMAL\*(C'\fR), usually more than enough. If you need to manage thousands of \f(CW\*(C`ev_stat\*(C'\fR watchers you might want to increase this value (\fImust\fR be a power of two). .IP "\s-1EV_COMMON\s0" 4 .IX Item "EV_COMMON" By default, all watchers have a \f(CW\*(C`void *data\*(C'\fR member. By redefining this macro to a something else you can include more and other types of members. You have to define it each time you include one of the files, though, and it must be identical each time. .Sp For example, the perl \s-1EV\s0 module uses something like this: .Sp .Vb 3 \& #define EV_COMMON \e \& SV *self; /* contains this struct */ \e \& SV *cb_sv, *fh /* note no trailing ";" */ .Ve .IP "\s-1EV_CB_DECLARE\s0 (type)" 4 .IX Item "EV_CB_DECLARE (type)" .PD 0 .IP "\s-1EV_CB_INVOKE\s0 (watcher, revents)" 4 .IX Item "EV_CB_INVOKE (watcher, revents)" .IP "ev_set_cb (ev, cb)" 4 .IX Item "ev_set_cb (ev, cb)" .PD Can be used to change the callback member declaration in each watcher, and the way callbacks are invoked and set. Must expand to a struct member definition and a statement, respectively. See the \fIev.h\fR header file for their default definitions. One possible use for overriding these is to avoid the \f(CW\*(C`struct ev_loop *\*(C'\fR as first argument in all cases, or to use method calls instead of plain function calls in \*(C+. .Sh "\s-1EXPORTED\s0 \s-1API\s0 \s-1SYMBOLS\s0" .IX Subsection "EXPORTED API SYMBOLS" If you need to re-export the \s-1API\s0 (e.g. via a dll) and you need a list of exported symbols, you can use the provided \fISymbol.*\fR files which list all public symbols, one per line: .Sp .Vb 2 \& Symbols.ev for libev proper \& Symbols.event for the libevent emulation .Ve .Sp This can also be used to rename all public symbols to avoid clashes with multiple versions of libev linked together (which is obviously bad in itself, but sometimes it is inconvinient to avoid this). .Sp A sed command like this will create wrapper \f(CW\*(C`#define\*(C'\fR's that you need to include before including \fIev.h\fR: .Sp .Vb 1 \& <Symbols.ev sed -e "s/.*/#define & myprefix_&/" >wrap.h .Ve .Sp This would create a file \fIwrap.h\fR which essentially looks like this: .Sp .Vb 4 \& #define ev_backend myprefix_ev_backend \& #define ev_check_start myprefix_ev_check_start \& #define ev_check_stop myprefix_ev_check_stop \& ... .Ve .Sh "\s-1EXAMPLES\s0" .IX Subsection "EXAMPLES" For a real-world example of a program the includes libev verbatim, you can have a look at the \s-1EV\s0 perl module (<http://software.schmorp.de/pkg/EV.html>). It has the libev files in the \fIlibev/\fR subdirectory and includes them in the \fI\s-1EV/EVAPI\s0.h\fR (public interface) and \fI\s-1EV\s0.xs\fR (implementation) files. Only the \fI\s-1EV\s0.xs\fR file will be compiled. It is pretty complex because it provides its own header file. .Sp The usage in rxvt-unicode is simpler. It has a \fIev_cpp.h\fR header file that everybody includes and which overrides some configure choices: .Sp .Vb 9 \& #define EV_MINIMAL 1 \& #define EV_USE_POLL 0 \& #define EV_MULTIPLICITY 0 \& #define EV_PERIODIC_ENABLE 0 \& #define EV_STAT_ENABLE 0 \& #define EV_FORK_ENABLE 0 \& #define EV_CONFIG_H <config.h> \& #define EV_MINPRI 0 \& #define EV_MAXPRI 0 .Ve .Sp .Vb 1 \& #include "ev++.h" .Ve .Sp And a \fIev_cpp.C\fR implementation file that contains libev proper and is compiled: .Sp .Vb 2 \& #include "ev_cpp.h" \& #include "ev.c" .Ve .SH "COMPLEXITIES" .IX Header "COMPLEXITIES" In this section the complexities of (many of) the algorithms used inside libev will be explained. For complexity discussions about backends see the documentation for \f(CW\*(C`ev_default_init\*(C'\fR. .Sp All of the following are about amortised time: If an array needs to be extended, libev needs to realloc and move the whole array, but this happens asymptotically never with higher number of elements, so O(1) might mean it might do a lengthy realloc operation in rare cases, but on average it is much faster and asymptotically approaches constant time. .RS 4 .IP "Starting and stopping timer/periodic watchers: O(log skipped_other_timers)" 4 .IX Item "Starting and stopping timer/periodic watchers: O(log skipped_other_timers)" This means that, when you have a watcher that triggers in one hour and there are 100 watchers that would trigger before that then inserting will have to skip roughly seven (\f(CW\*(C`ld 100\*(C'\fR) of these watchers. .IP "Changing timer/periodic watchers (by autorepeat or calling again): O(log skipped_other_timers)" 4 .IX Item "Changing timer/periodic watchers (by autorepeat or calling again): O(log skipped_other_timers)" That means that changing a timer costs less than removing/adding them as only the relative motion in the event queue has to be paid for. .IP "Starting io/check/prepare/idle/signal/child watchers: O(1)" 4 .IX Item "Starting io/check/prepare/idle/signal/child watchers: O(1)" These just add the watcher into an array or at the head of a list. .IP "Stopping check/prepare/idle watchers: O(1)" 4 .IX Item "Stopping check/prepare/idle watchers: O(1)" .PD 0 .IP "Stopping an io/signal/child watcher: O(number_of_watchers_for_this_(fd/signal/pid % \s-1EV_PID_HASHSIZE\s0))" 4 .IX Item "Stopping an io/signal/child watcher: O(number_of_watchers_for_this_(fd/signal/pid % EV_PID_HASHSIZE))" .PD These watchers are stored in lists then need to be walked to find the correct watcher to remove. The lists are usually short (you don't usually have many watchers waiting for the same fd or signal). .IP "Finding the next timer in each loop iteration: O(1)" 4 .IX Item "Finding the next timer in each loop iteration: O(1)" By virtue of using a binary heap, the next timer is always found at the beginning of the storage array. .IP "Each change on a file descriptor per loop iteration: O(number_of_watchers_for_this_fd)" 4 .IX Item "Each change on a file descriptor per loop iteration: O(number_of_watchers_for_this_fd)" A change means an I/O watcher gets started or stopped, which requires libev to recalculate its status (and possibly tell the kernel, depending on backend and wether \f(CW\*(C`ev_io_set\*(C'\fR was used). .IP "Activating one watcher (putting it into the pending state): O(1)" 4 .IX Item "Activating one watcher (putting it into the pending state): O(1)" .PD 0 .IP "Priority handling: O(number_of_priorities)" 4 .IX Item "Priority handling: O(number_of_priorities)" .PD Priorities are implemented by allocating some space for each priority. When doing priority-based operations, libev usually has to linearly search all the priorities, but starting/stopping and activating watchers becomes O(1) w.r.t. prioritiy handling. .RE .RS 4 .SH "AUTHOR" .IX Header "AUTHOR" Marc Lehmann <libev@schmorp.de>.